Datasheet: AEMC-L404 |
 |
| AEMC L404 Simple Logger II Description: |
 AEMC L404 Simple Logger II is a four channel event data logger. It is a cost effective, advanced design data logger incorporating features and functions not found in data loggers costing 2 to 3 times its price. Event data is stored only as the event occurs. It works with dry contact closure or 0-3 and 0-5VDC logic levels.

An internal memory allows storing over 50,000 events; more than enough for most data collection needs. Event measurement scaling is user programmable. Battery operation and compact size allows for installation in tight locations without the need for external power. A series of front panel LEDs provide a quick status of the logger’s state and memory usage.

DataView application software is included, providing real-time viewing of measurement data, even while recording. Instrument configuration, data storage and report generation from a pre-defined template or operator custom designed templates are also standard features.
 |
| AEMC L404 Simple Logger II Applications: |
| |
 Determine machinery run/down times
 |
| |
 Determine event sequencing
 |
| |
 Count events and record
 |
| |
 Record event duration
 |
| AEMC L404 Simple Logger II Characteristics: |
| |
 Four input channels
 |
| |
 Works with dry contact closure or 0-3 and 0-5V DC logic levels
 |
| |
 Programmable sample rates from 8 every second to 1 every day
 |
| |
 Stores up to 50,000 events in non-volatile memory
 |
| |
 Powered by standard alkaline batteries (included)
 |
| |
 Lightweight, compact, and fits anywhere
 |
| |
 5 LED indicators quickly and clearly display logger status
 |
| |
 Includes DataView software for data storage, real-time measurement display, analysis, and report generation
 |
| |
 Isolated USB communication cable
 |
| |
 EN 61010-1; 50V CAT III
 |
| AEMC L404 Simple Logger II Specifications: |
| Channels |
 Four
 |
| Input Connection |
 One 8 position removable screw type terminal block
 |
| Voltage Range |
 0 to 5V DC or contact closure
 |
| Sample Rate |
 Selectable from 125ms to 1 day
 |
| Storage Rate |
 Event triggered (maximum once every 2 sample periods)
 |
| Storage Modes |
 Event recording
 |
| Recording Length |
 15 minutes to 8 weeks, programmable using DataView
 |
| Memory |
 50,000 events (512KB). The recorded data is stored in non-volatile memory and retained even if the battery is low or removed
 |
| Communication |
 USB 2.0 optically isolated
 |
| Power Source |
 2 x 1.5V AA-cell Alkaline batteries
 |
| Battery Life |
 100 hours to > 45 days (dependent on storage rate/recording length)
 |
| Dimensions(without removable connector) |
 5.06 x 2.75 x 1.28" (129 x 70 x 32mm)
 |
| Weight (with battery) |
 6.4 Oz (180 grams)
 |
| Case |
 UL94-V0
 |
| Vibration |
 IEC 68-2-6 (1.5mm, 10 to 55 Hz)
 |
| Shock |
 IEC 68-2-27 (30G)
 |
| Drop |
 IEC 68-2-32 (1m)
 |
| Operating Temperature |
 14° to 122°F (-10° to 50°C)
 |
| Storage Temperature |
 -4° to 140°F (-20° to 60°C)
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |