Datasheet: AccuTools-BluVac |
 |
| AccuTools BluVac Digital Vacuum Gauge Description: |
 The AccuTools BluVac Digital Vacuum Gauge A10474 is a state-of-the-art digital vacuum gauge utilizing patent-pending technology to deliver the highest accuracy and resolution available.
Operating for up to 300 hours on a single 9V alkaline battery, the BluVac sports a large 1/2" numeric display and a bright blue backlight. The BluVac measures from 0—25,000 microns with 0.1 micron resolution below 10,000 microns.
The AccuTools BluVac Digital Vacuum Gauge is programmable, increasing your productivity on the job. Its Vacuum Leak Rate indicator shows both evacuation progress, and assists in determining the presence of leaks or moisture. Also included is a temperature indicator accurate to within 0.2F (0.1C).
Innovative Oil Sensor and Self-Diagnostics ensure accuracy. The BluVac and BluVac LTE are the only field-calibratable vacuum gauges that require no special equipment for calibration.
Includes: BluVac Digital Vacuum Gauge, detachable swivel hook, battery (one 9V alkaline), instruction manuel.
 |
| AccuTools BluVac Digital Vacuum Gauge Features: |
| |
 0 to 25,000 Micron Range with 0.1 Micron Resolution less than 10,000 Microns
 |
| |
 Measures Vacuum in Microns, Pascals, Millibar, Millitorr and mmHg
 |
| |
 Large, high-visibility back-lit LCD display
 |
| |
 Programmable with unique alarm feature
 |
| |
 Long battery life — Up to 300 Hours on one 9V alkaline battery
 |
| |
 Analog Vacuum Level Bar Graph
 |
| |
 Vacuum Leak Rate and Ambient Temperature Indicator
 |
| |
 Automatic Oil Sensor
 |
| |
 Measures Temperature in Fahrenheit and Celsius to 0.1
 |
| |
 Built-in memory retains all previous settings
 |
| |
 Rugged, Compact Design — About the Size of a Manifold Gauge
 |
| |
 Calibration Self Test — Can be field calibrated with no special equipment
 |
| |
 Sensor withstands overpressure up to 500 PSI
 |
| |
 Ideal for HVAC/R Service and Industrial Use
 |
| |
 Includes: BluVac Digital Vacuum Gauge, detachable swivel hook, battery (one 9V alkaline), instruction manual.
 |
| AccuTools BluVac Digital Vacuum Gauge Specifications: |
| Range |
 0 - 25,000 Microns (3333.1 Pa, 33.331 mBar, 25,000 mTorr, 25.000 mmHg)
 |
| Vacuum Accuracy |
 5% of reading +/- 5 Microns
 |
| Vacuum Resolution |
 0.1 Microns (at 0.0 to 9,999.9 Microns)
 |
| Vacuum Resolution |
 1 Microns (at 10,000.0 to 25,000 to 25,000 Microns)
 |
| Maximum Overpressure |
 500 PSI
 |
| Temperature Accuracy |
 0.2F (0.1C)
 |
| Temperature Resolution |
 0.1 Degree
 |
| Warm-up Time |
 Instant
 |
| Response Time |
 Instant
 |
| Power |
 One 9V Alkaline Battery
 |
| Battery Life |
 Up to 300 Hours
 |
| Operating Temperature |
 10F - 122F (-12C - 50C)
 |

Need Technical Advise? Please Call: 602-795-4033