Datasheet: AC75B |
 |
| Amprobe AC75B Clamp Meter Description: |
 Amprobe AC75B Digital Clamp Meter with Temperature is three tools in one: clamp meter,multimeter and thermometer. The extra features of the AC75B enable more specialized troubleshooting. Custom designed to make HVAC/R service, electrical and industrial maintenance tasks faster and easier. Amprobe AC75B combines a
heavy duty high-capacity 600 A clamp-on
meter with the most needed DMM functions
such as resistance, continuity and voltage
measurement for general electrical troubleshooting.

Amprobe AC75B then goes further
than typical clamp meters and adds extra
functions like a Type K digital thermometer,
a high capacitance range, and display backlight.
The extra features of the AC75B enable
more specialized troubleshooting such as
measuring flame rod safeguard current
and testing motor run/start capacitors.

Amprobe AC75B is fully safety engineered to US and Canadian standards and rated CAT III 600 V. Test leads rated CAT III 1000 V are included with the unit.
 |
| Amprobe AC75B Clamp Meter Characteristics: |
| |
 600 A AC current
 |
| |
 4000 uA DC current for flame rod testing
 |
| |
 Measures temperature to 1000 Degrees F (400 Degrees C)
 |
| |
 Includes Type K thermocouple probe
 |
| |
 40 Mohm resistance
 |
| |
 Capacitance to 4000 uF for motor capacitance run/start testing
 |
| |
 Continuity beeper
 |
| |
 4000-count large digit display
 |
| |
 Jaw size 35mm (1.3 inches)
 |
| |
 Auto power off
 |
| |
 Full overload protection
 |
| |
 One-year warranty
 |
| |
 CAT II 1000 V, CAT III 600 V safety rated
 |
| Amprobe AC75B Clamp Meter Specifications: |
| AC A |
 (50/60 Hz) Ranges 400 A, 600 A
Accuracy 0 to 100 A +/- (1.9 % + 2 A)
Accuracy 100 to 400 A +/- (1.9 % + 1 A)
Accuracy 400 to 600 A +/- (2.5 % + 7 A)
Resolution 0.1A
 |
| DC A |
 DC A Ranges 400, 4000 uA
Accuracy +/-(1.0 %+2 d)
Resolution 0.1 uA
ACV (50 to 500 Hz)
Ranges 4, 40, 400, 750 V
Accuracy +/-(1.5 %+5 d)
Resolution 1 mV
 |
| DCV |
 Ranges 4, 40, 400, 1000 V
Accuracy +/-(0.9 %+2 d)
Resolution 1 mV
 |
| Resistance |
 Ranges 400, 4 k, 40 k, 400 k, 4 M, 40 Mohm
Accuracy 400 Ohms +/-(1.0 % + 2 d)
Accuracy 4 Ohms to 400 Ohms +/-(0.7 % + 2 d)
Accuracy 4 Mohms +/-(1.0 % + 2 d)
Accuracy 40 Mhms +/-(1.5 % + 2 d)
Resolution 0.1 Ohm
 |
| Diode Test |
 Max test current/Accuracy 1.5 mA +/-(1.5 % + 5 d)
Open circuit voltage 3 V
 |
| Continuity |
 Beeper Threshold approx. 200 Ohms
Indicator 2 kHz tone buzzer
 |
| Capacitance |
 Ranges 4 n, 40 n, 400 n, 4 u, 40 u, 400 u, 4 mF
Accuracy 4 n +/-(3.0 % + 20 d)
Accuracy All other ranges +/-(2.0 % + 8 d)
Resolution 1 pF
 |
| Temperature |
 Ranges 0 C, 400 Degrees C (32 F, 750 F, 1000 Degrees F)
Accuracy -40 C to .1 Degree C +/-(1 % + 4 Degrees C)
Accuracy 0 C to 400 Degrees C +/-(1 % + 3 Degrees C)
Accuracy -40 F to 32 Degrees F +/-(1 % + 8 Degrees F)
Accuracy 32 F to 750 Degrees F +/-(1 % + 6 Degrees F)
Accuracy 750 F to 1000 Degrees F +/-(2 % + 8 Degrees F)
Resolution 0.1 C/1 Degree F
 |
| Operating temperature |
 0 C to 50 Degrees C
 |
| Maximum jaw opening |
 Up to 1.3 inches (35 mm)
 |
| Safety |
 Designed to meet IEC 1010-1 and IEC 61010-2-032, Class 2 and pollutiondegree 2 indoor use. Complies with CE and CSA 22.2 No. 1010-1 andNo. 1010.2.032 requirements.
 |
| Battery life |
 400 hours (alkaline)
 |
| Power requirement |
 Standard 9 V battery NEDA 1604, JIS 006P
 |
| Dimensions |
 84 mm (W) x 212 mm (L) x 40 mm (D) (3.3 x 8.4 x 1.6 inches)
 |
| Weight |
 Approx. 390 g (15 oz.)
 |