Datasheet: ACD-10 Pro |
 |
| Amprobe ACD-10 Pro Digital Clamp Multimeter Description: |
 Amprobe ACD-10 Pro Digital Clamp Multimeter comes equipped with: Average Sensing, Measures AC Voltage, Measures DC Voltage, Measures AC Current to 400A, etc. Discontinued product - Replaced by Amprobe AC75B.
 |
| Amprobe ACD-10 Pro Digital Clamp Multimeter Characteristics: |
| |
 Overload protected
 |
| |
 In Rush Current Measurement
 |
| |
 AC and DC Voltage to 600V
 |
| |
 AC Current to 400A
 |
| |
 Resistance to 40M? with
 |
| |
 Continuity Buzzer
 |
| Amprobe ACD-10 Pro Digital Clamp Multimeter Features: |
| Weight: |
 0.95 lb
 |
| Safety: |
 CE, UL, Cat II 600 V and Cat III 300 V
 |
| Size: |
 8.00x4.50x2.00 inch
 |
| Warranty: |
 Limited Life Time Warranty
 |
| Amprobe ACD-10 Pro Digital Clamp Multimeter Specifications: |
| AC Voltage: |
 .000V, 40.00V, 400.0V, 600V (1.5% Rdg + 5 LSD) @ 4.000V, 40.00V, 400.0V**
 |
| DC Voltage: |
 0-400.0mV, 4.000V, 40.00V, 400.0V, 600V (0.5% Rdg + 3 LSD) @ 4.000V, 40.00V, 400.0V**
 |
| AC Current: |
 0-40.00A, 400.0A (1.9% Rdg + 8 LSD)**
 |
| Resistance with Continuity Buzzer: |
 0-400.0Ω 4.000kΩ, 40.00kΩ 400.0kΩ, 0-4.000MΩ, 40.00MΩ (0.6% Rdg + 4 LSD) @ 4.000kΩ, 40.00kΩ, 400.0kΩ**
 |
| Capacitance: |
 500.0nF, 5.000 F, 50.00 F, 500.00 F, 3000 F (3.5% Rdg + 6 LSD)
 |
| Frequency (Using Jaw or Test Leads): |
 40 - 400Hz with Jaw, 10Hz - 2kHz with test leads (0.5% Rdg + 4 LSD)
 |

Need Technical Advise? Please Call: 602-795-4033