Datasheet: ACD-15-PRO |
 |
| Amprobe ACD-15 Pro Digital Clamp on Multimeter Description: |
 Amprobe ACD-15 2000A Pro Digital Clamp on Multimeter performs non-contact voltage level detection and diode test.

There are plenty of look-alike clamp multimeters on the market, but professionals choose genuine Amprobe. It’s really all about choices.

Amprobe Instruments offers you a full line of Clamp Multimeters (Digital Clamp Meters) for Volts-Amp Resistance, Multimeter, Recording, Power and Power Quality applications. So go with the choice of professionals.

Amprobe Instruments famous Red, Rubber, Ribs make it easy to "grab the Amprobe" you need to get the job done right.
 |
| Amprobe ACD-15 Pro Digital Clamp on Multimeter Characteristics: |
| |
 Measurements: AC/DC Voltage up to 600V, AC Current up to 2000A, Resistance, Frequency and Capacitance
 |
| |
 Non-contact Voltage Level Detection
 |
| |
 Diode Test
 |
| |
 Audible continuity
 |
| |
 Auto-check feature automatically selects DCV, ACV or Resistance
 |
| |
 Auto and manual ranging
 |
| |
 Auto power off
 |
| |
 Low battery indication
 |
| |
 Data hold
 |
| |
 Large, easy to read LCD display
 |
| |
 Accommodates conductors up to 1.77 inches (45mm) in diameter
 |
| |
 Carrying case, test leads, batteries (installed) and manual included
 |
| |
 Voltage overload protection for all functions up to 600V AC/DC
 |
| Amprobe ACD-15 Pro Digital Clamp on Multimeter Features: |
| Safety: |
 CAT III 600V
 |
| Instruction Manual: |
 Yes
 |
| AC / DC Voltage Basic Accuracy: |
 +/-(2.0% Rdg + 5 LSD) @ DC & 50 / 60 Hz**
 |
| Frequency: |
 10Hz to 1kHz
 |
| Frequency Basic Accuracy: |
 0.5%+4d
 |
| Capacitance: |
 100.0, 1000 nF 10.00, 100.0, 2000 uF
 |
| Capacitance Basic Accuracy: |
 3.5%+5d
 |
| Replacement Parts: |
 Supplied with product
 |
| MTL-90B: |
 Set of Test Leads with Alligator Clips
 |
| SVU: |
 CASE, UNIVERSAL
 |
| Amprobe ACD-15 Pro Digital Clamp on Multimeter Specifications: |
| AC Current: |
 400.0 / 2000 A
 |
| AC Current Basic Accuracy: |
 +/-(1.5% Rdg + 5 LSD) @ 50 and 60Hz
 |
| AC / DC Voltage: |
 6.000 / 60.00 / 600V
 |
| Resistance: |
 6.000 /60.00 / 600.0 kOhms 6.000 MOhms
 |
| Resistance Basic Accuracy: |
 +/-(1.0% Rdg + 4 LSD) @ 60.00 to 600.0 kOhms ranges **
 |
| Non-contact Voltage: |
 15V to 85V, 40V to 130V,60V to 210V,90V to 300V,Above 120V
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |