Datasheet: ACD31P |
 |
| Amprobe ACD-31P Clamp-on Power Meter Description: |
 Amprobe ACD-31P Clamp-on Power Meter combines the standard features of professional clamp-on meter, with full Power analyzing capabilities. The ACD-31P measures: Active (W), Reactive (VAR) and Apparent (VA) Powers along with dual display Power Factor readout. Increase measuring efficiency with an optional PC interface kit.
 |
| Amprobe ACD-31P Clamp-on Power Meter Characteristics: |
| |
 TRMS sensing
 |
| |
 AutoVA - Auto Selection of AC Volts, DC Volts or AC Amps
 |
| |
 AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency
 |
| |
 Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout,Temperature
 |
| |
 Optional PC interface capability (RS-232 KIT2)
 |
| |
 Audible continuity
 |
| |
 Auto power off
 |
| |
 Automatic polarity
 |
| |
 Low battery indication
 |
| |
 Peak hold
 |
| |
 Data hold
 |
| |
 Large, easy to read LCD display
 |
| |
 Accommodates conductors up to 1.77” (45mm) in diameter
 |
| |
 Carrying case, test leads, batteries (installed),thermocouple and manual included
 |
| |
 Voltage overload protection for all functions up to 600V AC/DC
 |
| Amprobe ACD-31P Clamp-on Power Meter Features: |
| Safety: |
 CAT III 600V
 |
| Instruction Manual: |
 Yes
 |
| Replacement Parts: |
 Supplied with product
 |
| MTL-90B: |
 Set of Test Leads with Alligator Clips
 |
| TPK-59: |
 Thermocouple
 |
| SV-U: |
 CASE, UNIVERSAL
 |
| Amprobe ACD-31P Clamp-on Power Meter Specifications: |
| TRMS: |
 Yes
 |
| AC Current: |
 40.0 / 400.0 / 1000 A
 |
| AC Current Basic Accuracy**: |
 +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz
 |
| DC Voltage: |
 600.0V
 |
| DC Voltage Basic Accuracy**: |
 +/-(0.5% Rdg + 5 LSD)
 |
| AC Voltage: |
 600.0V
 |
| AC Voltage Basic Accuracy**: |
 +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz
 |
| Resistance : |
 999.9 Ohms
 |
| Resistance Basic Accuracy**: |
 +/-(1.0% Rdg + 6 LSD)
 |
| Frequency: |
 5.00Hz to 500.0Hz
 |
| Frequency Basic Accuracy**: |
 +/-(0.5% Rdg +4 LSD)
 |
| Active Power (W): |
 0 to 600.0 kW
 |
| Active Power (W) Basic Accuracy**: |
 +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
 |
| Reactive Power (VAR): |
 0 to 600.0 kVAR
 |
| Reactive Power (VAR) Basic Accuracy**: |
 +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
 |
| Apparent Power (VA): |
 0 to 600.0 kVA
 |
| Apparent Power (VA) Basic Accuracy**: |
 +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th
 |
| Power Factor: |
 0.10 to 0.99
 |
| Power Factor Basic Accuracy**: |
 +/- 3 LSD @ Harmonics Fund to 21th
 |
| Temperature: |
 -58 F to 572 F (-50 C to 300
 |
| Temperature Basic Accuracy**: |
 +/-(2.0% Rdg + 6F) +/-(2.0 % Rdg + 3C)
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |