| Datasheet: |
 |
| Bacharach Tru Pointe 19-8106 Refrigerant Leak Detector Description: |
 Bacharach Tru Pointe 19-8106 Refrigerant Leak Detector is designed to be instantly responsive to all refrigerants. It is even accurate when used in environments where high levels of refrigerant vapors are present. No manual sensitivity adjustments are necessary during the inspection process. Simply turn the unit on, and let it mark the spot.

The Tru Pointe is suitable for HVAC Service Technicians, Refrigerant Service Technicians, Plant Maintenance Departments, Automotive Service Facilities, and Refrigerant & Environmental Chamber Manufactures who are in need of a small, lightweight and rugged instrument that is capable of detecting and then pinpointing small to large refrigerant leaks in tight spaces such as those found in refrigeration units and automobile engine compartments.
 |
| Bacharach Tru Pointe 19-8106 Refrigerant Leak Detector Features: |
| |
 Detects all CFC, HFC, and HCFC refrigerants.
 |
| |
 Instantaneous response time.
 |
| |
 Innovative sensor replacement design.
 |
| |
 Patented Heated Diode Sensor Technology.
 |
| |
 Battery-powered with low battery indication.
 |
| |
 Long-life, DC brushless fan.
 |
| |
 High and low-sensitivity modes.
 |
| |
 Automatic zero and background compensation.
 |
| |
 No user calibration required.
 |
| |
 Audible and visual leak detection.
 |
| |
 Easy to use, one-handed operation.
 |
| Bacharach Tru Pointe 19-8106 Refrigerant Leak Detector Specifications: |
| Refrigerants Detected: |
 All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas).
 |
| Sensing Element: |
 Patented Heated Diode, U.S. Patent No. 5,932,176.
 |
| Alarm Sensitivity: |
 0.1 oz/year of R134a (hardest to detect refrigerant).
 |
| Alarm Types: |
 Variable-intensity audible and visual.
 |
| Power Source: |
 Two ‘D’ disposable alkaline batteries.
 |
| Warm-up Time: |
 10 seconds.
 |
| Response Time: |
 Instantaneous.
 |
| Battery Life: |
 8 to13 hours continuous operation, dependent on
sensitivity mode.
 |
| Probe: |
 14" (356mm) flexiable.
 |
| Size: |
 2" W x 9.38" L x 2.5" H (50.8 x 238.3 x 63.5 mm.
 |
| Weight: |
 1.16 lbs. (0.53 kg) with batteries.
 |
| CE-Mark: |
 Independently tested.
 |
| Agency Approvals: |
 UL listed in accordance with SAE J1627.
 |
| Warranty: |
 One year, including sensor.
 |
| Contains: |
 Tru Pointe, instruction manual, 2 ‘D’ batteries and a hard carrying case.
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |