Datasheet: Dent-DATAPro-Datasheet |
 |
| Dent Instruments DATApro 4VDC Power Quality Datalogger Meter Description: |
 Dent Instruments DATApro model 4VDC Data Logger and Recorder with 4 Low Voltage DC Recording Channels.

The voltage data logger and recorder model DATAproâ„¢ is a recording 4 channel power quality recorder and data logger that is designed to measure, store and analyze up to 100,000 records of data from all types of sensors in most any environment like gas, water, electric, steam,
HVAC, compressed air, solid or liquid waste, security, weather, or manufacturing process lines.

The power quality meter DATAproâ„¢ has the following features: Easy to use, Windowsâ„¢ based software graphically displays recorded data, performs analyses and allows automatic, remote data collection via Internet, wired or wireless LAN systems, or telephone modems. Data is easily exported to popular spread-sheets and databases for special analyses. UL listed and available in weather-tight enclosure. Made in the USA.
 |
| Dent Instruments DATApro 4VDC Power Quality Datalogger Meter Applications: |
| |
 Air Quality Monitoring to measure factors within workspace environments such as CO2,
carbon monoxide, humidity, and temperature
 |
| |
 Pulse Measurements for Flow Applications such as gas, water and/or steam
 |
| |
 Pulse Counts for KYZ Meter Output to log consumption as measured with revenue
meters
 |
| |
 True RMS Current Reading for monitoring up to 4 branch circuits
 |
| |
 Time of Use Monitoring for demand measurements
 |
| Dent Instruments DATApro 4VDC Power Quality Datalogger Meter Characteristics: |
| Versatile |
 Accepts 4 channels of current, 0-3000A or pulse count, or temperature
 |
| Smart |
 Measures True RMS (current only)
 |
| Programmable |
 User defined recording intervals of 3, 15,30 seconds, 1, 5, 15, 30
minutes, and 1, 12, 24 hours and the ability to select maximum, minimum, average,
instantaneous, or all parameters
 |
| Powerful |
 With expandable memory from 128kB (~25,000 records) to 512kB
(~100,000 records) allowing months of logging
 |
| Accurate |
 Better than <0.5% accuracy
 |
| Communications |
 Via direct RS232 hookup to PC, through internal modem allowing
for remote communications via land lines or cellular networks with AutoPoll ™ or
AutoHost ™ capabilities, or through wired or unwired LAN systems
 |
| Switchable Power |
 Battery or line power providing options in varying installations
applications
 |
| Window Based Software Package |
 ELOG™ software for ease of programming, set-up,
communicating, data retrieval and analysis. Various analysis and graphing features, and
easy exporting to any ASCII format data file like Excel
 |
| Clever |
 Alarm capability to detect, download data and notify the user once
predetermined high or low points are meet within any measurement parameter
 |
| Quick and Easy Installation |
 Installs within minutes and is equipped with strong
magnetic strips for securing within panels
 |
| Compact and Tough |
 Made of heavy plastic, only 3” x 6” x 2” and just 12 ounces to
easily fit inside panels for safety and convenience
 |
| Weather Beater |
 Available in weather tight enclosure to meet stringent NEMA 4
applications
 |
| Acceptance |
 UL Listed for USA & Canada and CE compliance for Europe
 |
| Warranty |
 One Year Manufacturer's Warranty
 |
| Dent Instruments DATApro 4VDC Power Quality Datalogger Meter Specifications: |
| Specifications Common To All Models Of DATApro: |

 |
| Accuracy |
 Better Than 1% (<0.5% typical) exclusive of sensor error
 |
| Analog Sampling Rate |
 1 second on external DC power, 1 minute when on internal battery
 |
| Battery Life |
 ~3 years, LED indicator of low battery charge
 |
| Clock |
 Crystal controlled internal Real Time Clock, 20 ppm (<1
min/month)
 |
| Communication |
 RS-232 to PC via 9 pin null modem cable
 |
| Communication Rate |
 1200, 2400, 4800, 9600, 19200, 28800, 57600 baud
 |
| Data Formats |
 ASCII and Binary
 |
| Digital Sampling Rate |
 10 Hz Maximum, Interrupt driven
 |
| Dimensions |
 8 X 15 X 6 cm (3.2” X 5.9” X 2.4”) Indoor Enclosure
 |
| ELOG Software |
 Programs Logger, Displays Current Metered Values,
Retrieves Data
 |
| Enclosure |
 Indoor: High Impact ABS Plastic, UL 94-V0 flame rating
Outdoor: Weather tight enclosure, Polycarbonate UL 94-V2
flame rating
 |
| Humidity |
 5% to 95% non-condensing
 |
| Indicators |
 2 LEDs: Green to signal when logging, Red to signal low
battery
 |
| Measurements |
 Maximum, Minimum, Average, Instantaneous (Temperature,
Current,
Milliamps and Volts DC), Count, Run-Time, Duty-Cycle, On-Time
(Pulse/Digital)
 |
| Memory |
 128 kBytes standard (~25,000 readings), or 512 kB
(~100,000 readings)
 |
| Memory Types |
 Ring (continuous, write newest over oldest), or Linear (stop
when full)
 |
| Modem |
 Internal 1200, 2400, 4800, 9600, 14400 baud, auto-answer,
auto-dial
 |
| Number of Channels |
 4
 |
| Operating Temperature |
 -7 to + 60 oC (20 to 140 oF)
 |
| Power |
 Internal Lithium Battery, For external power use a Listed
(US/Canada) or
Certified (non-US) power supply rated 9 VDC minimum 150
mA and
marked ‘Class 2,’ ‘Limited Power Source,’ or ‘LPS’
 |
| Recording Intervals |
 3, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1, 12,
24 hours
 |
| Resolution |
 12 bit A/D (1 part in 4,096): 0.01 Amp, 0.1 oF or oC, 1
Count
 |
| Weight |
 0.4 kg (11 ounces) without modem
 |
| Specifications specific to model 4VDC: |

 |
| 4 DC Voltage Channels |
 0-10 Volts DC, 0.01V Resolution
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |