Datasheet: Dent-ELITEPro-Datasheet |
 |
| Dent Instruments E-KIT-3000 ELITEpro Power Quality Meter Analyzer Kit Description: |
 Dent Instruments E-KIT-3000 ELITEpro Kit includes recorder, 3000 Amp CT clamps, indoor communication package and carrying case.

The ELITE pro helps pinpoint electric usage and quantify consumption by measuring, storing, and analyzing Volts, Amps, Watts, Volt-Amps (VA), Volt-Amps reactive (VAR), Kilowatts (kW), Kilowatt
Hours (kWh), Power Factor and harmonics; 144 different parameters.

It can monitor up to four singlephase loads or two three-phase Delta loads, or one three-phase Wye load. It includes four channels of current (0-6,000 amps), and three channels of voltage (0-600V ac or dc).

The ELITE pro also offers
some power quality features such as the ability to view voltage, current, and power waveforms.

It will calculate harmonics from DC through the 63rd then report total harmonic distortion (THD), crest factor and peak voltage & current.

The ELITEpro can be mounted anywhere and with its wide range of recording interval�s and a storage capacity of up to 100,000 records, is ideal for both short-term projects or long-term
studies.

Easy to use, Windows� based software graphically displays recorded data, performs analyses and allows automatic, remote data collection via Internet, wired or wireless LAN systems, or telephone modems.

Data is easily exported to popular spread-sheets and databases for special analyses.

UL listed and available in weather-tight enclosure. Made in the USA.
 |
| Dent Instruments E-KIT-3000 ELITEpro Power Quality Meter Analyzer Kit Characteristics: | | |
 Kit includes ELITEpro recorder, (3) 3000 Amp CT clamps, indoor communication package and carrying case
 |
| |
 Versatile - one instrument to measure single or three phase loads
 |
| |
 Smart - measures kWh, kW, Volts, Amps, kVA, kVAr, watts, VA, VAR, Power
Factor, wave form capture & harmonics conten
 |
| |
 Programmable - user defined recording intervals of 3, 15, 30 seconds, 1, 2, 5, 10, 15,
20, 30 minutes, and 1, 12, 24 hours and the ability to select maximum, minimum,
average, instantaneous, or all parameters
 |
| |
 Powerful - expandable memory from 128kB (~25,000 records) to 512kB (~100,000
records) allowing for months of logging
 |
| |
 Accurate - better than <0.5% accuracy
 |
| |
 Communications - via direct RS232 hookup to PC, through internal modem allowing
for remote communications via land lines or cellular networks including AutoPoll™ or
AutoHost™ capabilities or through wired or wireless LAN systems and the Internet
 |
| |
 Switchable Power - battery or auxillary power providing options in varying
installations applications
 |
| |
 Window Based Software Package - ELOG™ software for ease of programming, set-up,
communicating, data retrieval and analysis. Various analysis and graphing features with
easy exporting to any ASCII format data file like Excel
 |
| |
 Clever - alarm capability to detect, download data and notify the user once
predetermined high or low points are meet within any measurement parameter
 |
| |
 Quick and Easy Installation - installs within minutes and is equipped with strong
magnetic strips for securing inside panels, disconnects or load centers. Hanging brackets
included on weather-tight enclosure
 |
| |
 Compact and Tough - made of heavy plastic, only 3” x 6” x 2” and just 12 ounces to
easily fit inside panels for safety and convenience
 |
| |
 Weather Beater - available in weather tight enclosure to meet stringent NEMA 4
applications
 |
| |
 Acceptance - UL Listed for USA & Canada and CE compliance for Europe
 |
| Dent Instruments E-KIT-3000 ELITEpro Power Quality Meter Analyzer Kit Specifications: | | 3 Voltage Channels |
 0-600 Volts AC or 0-800 Volts DC, Higher AC voltages can
be measured with a Potential (voltage) Transformer
 |
| 4 Current Channels |
 0-333 mV AC or 0-600 mV DC, Corresponding to 0-6,000+
Amps depending on current transformer selected
 |
| Current Transformers |
 Uses voltage output CTs (0-333mVAC) for maximum safety.
Compatible with DENT Instruments DATA proTM and Energy
Logger CTs
 |
| Measurement Type |
 True RMS using high-speed digital signal processing (DSP)
 |
| Line Frequency |
 60, 50, or 400 Hz and DC
 |
| Harmonic Sensitivity |
 1st through 50th
 |
| Waveform Sampling |
 128 times per cycle
 |
| Measurements |
 Volts, Amps, kW, kVAR, kVA, and Power Factor
Maximum, Minimum, Average, (All Parameters) also kWh,
kVARh, kVAh, Ah
 |
| Harmonics |
 DC and Fundamental through 50th (odd and even), Total
Harmonic Distortion, Crest Factor, for both Current and
Voltage
 |
| Waveform Capture |
 Voltage, Current, Power
 |
| Accuracy |
 Better Than 1% (<0.5% typical) for V, A, kW, kVAR, kVA, PF
exclusive of sensor error
 |
| Resolution |
 12 bit A/D plus sign (1 part in 4,096): 0.01 Amp, 0.1 Volt, 1
watt, 1 VAR, 1 VA, 0.01 Power Factor
 |
| Memory |
 128 kBytes standard (~25,000 readings), or 512 kB
(~100,000 readings)
 |
| Memory Types |
 Ring (continuous, write newest over oldest), or Linear (stop
when full)
 |
| Recording Intervals |
 3, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1, 12,
24 hours
 |
| Indicators |
 2 LEDs: Green to signal when logging, Red to signal low
battery
 |
| Communication |
 RS-232 to PC via 9 pin null modem cable
 |
| ELOG Software |
 Programs Logger, Displays Current Metered Values,
Retrieves Data
 |
| Data Formats |
 ASCII and Binary
 |
| Power |
 Internal Lithium Battery; For external power use a Listed
(US/Canada) or
Certified (non-US) power supply rated 9 VDC minimum 150
mA and
marked ‘Class 2,’ ‘Limited Power Source,’ or ‘LPS’
 |
| Battery Life |
 ~3 years, LED indicator of low battery charge
 |
| Analog Sampling Rate |
 3 seconds on external DC power, 1 minute when on internal
battery
 |
| Clock |
 Crystal controlled internal Real Time Clock, 20 ppm (<1
min/month)
 |
| Operating Temperature |
 -7 to + 60 oC (20 to 140 oF)
 |
| Humidity |
 5% to 95% non-condensing
 |
| Enclosure |
 Indoor: High Impact ABS Plastic, UL 94-V0 flame rating
Outdoor: Weather tight enclosure, Polycarbonate UL 94-V2
flame rating
 |
| Weight |
 0.4 kg (11 ounces) without modem
 |
| Dimensions |
 8 X 15 X 6 cm (3.2” X 5.9” X 2.4”) Indoor Enclosure
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |
|