| Fluke 1507 Insulation Resistance Tester 2427890 Description: |
 Fluke 1507 Insulation Resistance Tester (Mfg Part No. 2427890) are compact, rugged, reliable, and easy to use. With their multiple test voltages, this insulation resistance tester is ideal for many troubleshooting, commissioning, and preventative maintenance applications.
 |
| Fluke 1507 Insulation Resistance Tester 2427890 Applications: |
| |
 Troubleshooting
 |
| |
 Commissioning
 |
| |
 Preventative maintenance
 |
| Fluke 1507 Insulation Resistance Tester 2427890 Characteristics: |
| |
 Repetitive or hard-to-reach testing is easy with the remote test probe
 |
| |
 Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
 |
| |
 Auto-discharge of capacitive voltage for added user protection
 |
| |
 Save battery power with auto power off
 |
| |
 Read measurements easily with large, backlit display
 |
| |
 CAT IV 600 V overvoltage category rating
 |
| |
 Remote probe, test leads, probes, alligator clips, holster and user documentation included with each tester
 |
| |
 Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
 |
| |
 Four AA alkaline batteries (NEDA 15 A or IEC LR6)
 |
| |
 Automatic calculation of Polarization Index and Dielectric Absorption Ratio
 |
| |
 Compare (Pass/Fail) function
 |
| |
 One year warranty
 |
| Fluke 1507 Insulation Resistance Tester 2427890 Specifications: |
| Maximum voltage applied to any terminal: |
 600 V AC RMS or DC
 |
| Storage Temperature |
 -40 °C to 60 °C (-40 °F to 140 °F)
 |
| Operating Temperature |
 -20 °C to 55 °C (-4 °F to 131 °F)
 |
| Temperature Coefficient |
 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
 |
| Relative Humidity |
 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
 |
| Vibration |
 Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
 |
| Shock |
 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
 |
| Electromagnetic compatibility: |
 In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
 |
| Safety |
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
 |
| Certifications: |
 CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
 |
| Batteries |
 Four AA batteries (NEDA 15A or IEC LR6)
 |
| Battery Life |
 Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
 |
| Size |
 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
 |
| Weight |
 550 g (1.2 lb)
 |
| IP Rating |
 IP40
 |
| Altitude |
 Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m
 |
| Over-range capability: |
 110 % of range
 |
| AC/DC Voltage Measurement: |

 |
| Accuracy: |
 Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits) ± (2 % + 3)
 |
| Input impedance |
 3 MΩ (nominal), < 100 pF
 |
| Common mode rejection ratio (1 kΩ unbalanced) |
 > 60 dB at dc, 50 or 60 Hz
 |
| Overload Protection |
 600 V RMS or DC
 |
| Earth bond resistance measurement: |

 |
| Range/Resolution |
 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ
 |
| Accuracy |
 ± (1.5 % + 3)
 |
| Overload Protection |
 2 V RMS or DC
 |
| Open Circuit Test Voltage |
 > 4.0 V, < 8 V
 |
| Short circuit current |
 > 200.0 mA
 |
| Insulation specifications: |

 |
| Measurement Range |
 0.01 MΩ to 10 GΩ
 |
| Test voltage |
 50 V, 100 V, 250 V, 500 V, 1000 V
 |
| Test Voltage Accuracy |
 + 20 %, - 0 %
 |
| Short circuit current |
 1 mA nominal
 |
| Auto Discharge |
 Discharge time < 0.5 second for C = 1 °F or less
 |
| Live circuit indicator |
 Inhibit test if terminal voltage > 30 V prior to initialization of test
 |
| Maximum Capacitive Load |
 Operable with up to 1 °F load
 |
| Measure Accuracy: |
 50 V: ±(3 % + 5)
100 V: ±(3 % + 5)
250 V: ±(1.5 % + 5)
500 V: ±(1.5 % + 5)
1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ
 |

Need Technical Advise? Please Call: 602-795-4033