Datasheet: Fluke-1577-1587-Insulaiton-MM |
 |
| Fluke 1577 Insulation Multimeter Description: |
 Fluke 1577 Insulation Multimeter (Mfg Part No. 2157280) combines a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit. This insulation multimeter provides maximum versatility for both troubleshooting and preventative maintenance.
 |
| Fluke 1577 Insulation Multimeter Characteristics: |
| Virtual Product Demo |
 Clamp Meter Demo
 |
| |
 Auto discharge of capacitive voltage
 |
| |
 AC/DC Voltage
 |
| |
 DC millivolts
 |
| |
 AC/DC milliamps
 |
| |
 Continuity
 |
| |
 Remote probe, test leads, alligator clips
 |
| |
 Rugged, utility hard case
 |
| |
 Auto power off to save battery power
 |
| |
 True-rms
 |
| |
 Large display with backlight
 |
| |
 Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
 |
| |
 CAT III 100V, CAT IV 600V measurement category
 |
| |
 Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work
 |
| |
 Three-year warranty
 |
| Fluke 1577 Insulation Multimeter Specifications: |
| Operating temperature |
 –20 °C to +55 °C
 |
| Storage temperature |
 -40°C to +60°C
 |
| Humidity (Without Condensation) |
 0% - 95% (10 °C – 30 °C)
0% - 75% (30 °C – 40 °C)
0% - 40% (40 °C – 55 °C)
 |
| Operating Altitude |
 Operating Altitude 2000 m
 |
| Overvoltage category |
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
 |
| Agency Approvals |
 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
 |
| Size |
 203 x 100 x 50 mm (with holster)
 |
| Weight |
 624 g
 |
| Battery life Alkaline |
 Meter use: 1000 hours
Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
 |
| IP Rating |
 IP40
 |
| Voltage DC: |
 Maximum Voltage: 1000 V
 |
| |
 Accuracy: ±(2%+3)
 |
| |
 Maximum Resolution: 0.001V
 |
| Voltage AC : |
 Maximum Voltage: 1000 V
 |
| |
 Accuracy ±(2%+3)
 |
| |
 Maximum Resolution: 0.1 mV
 |
| Current DC: |
 Maximum Amps: 400mA
 |
| |
 Amps Accuracy: ±(1.0%+2)
 |
| |
 Maximum Resolution: 0.01 mA
 |
| Current AC: |
 Maximum Amps 400mA
 |
| |
 Amps Accuracy: ±(2.0%+2)*
* 1kHz bandwidth
 |
| |
 Maximum Resolution 0.01 mA
 |
| Resistance |
 Maximum Resistance: 50 MΩ
 |
| |
 Accuracy: ±(1.2%+2)
 |
| |
 Maximum Resolution: 0.1Ω
 |
| Insulation Test: |

 |
| Minimum Test Current @ 1kΩ/V: |
 1mA
 |
| Test Voltages: |
 500, 1000 V
 |
| Maximum Resistance per Test Voltage: |
 1000V: 600 MΩ
 |
| Maximum Resolution per Test Voltage: |
 50V: 0.01 MΩ
100V: 0.01 MΩ
250V: 0.1 MΩ
500V: 0.1 MΩ
1000V: 0.1 MΩ
 |
| Accuracy per Test Voltage: |
 50V: ±(3 % + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: ±(2.0 % + 5)
1000V: ±(2.0 % + 5)
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |