Datasheet: Fluke-1577-1587-Insulation-MM |
 |
| Fluke 1587 Insulation Multimeter Description: |
 Fluke 1587 Insulation Multimeter (Mfg Part No. 2157271) combines a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit. This insulation multimeter provides maximum versatility for both troubleshooting and preventative maintenance.
 |
| Fluke 1587 Insulation Multimeter Characteristics: |
| |
 Auto discharge of capacitive voltage
 |
| |
 AC/DC Voltage
 |
| |
 DC millivolts
 |
| |
 AC/DC milliamps
 |
| |
 Continuity
 |
| |
 Remote probe, test leads, alligator clips
 |
| |
 Rugged, utility hard case
 |
| |
 Auto power off to save battery power
 |
| |
 True-rms
 |
| |
 Large display with backlight
 |
| |
 Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
 |
| |
 CAT III 100V, CAT IV 600V measurement category
 |
| |
 Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work
 |
| |
 Three-year warranty
 |
| Virtual Product Demo |
 Clamp Meter Demo
 |
| |
 Insulation test smoothing reading
 |
| |
 Frequency
 |
| |
 Capacitance
 |
| |
 Diode test
 |
| |
 Temperature
 |
| |
 Min/Max
 |
| |
 Low pass filter (for work on VSD's)
 |
| |
 K-type thermocouple
 |
| Fluke 1587 Insulation Multimeter Specifications: |
| Operating temperature |
 –20 °C to +55 °C
 |
| Storage temperature |
 -40°C to +60°C
 |
| Humidity (Without Condensation) |
 0% - 95% (10 °C – 30 °C)
0% - 75% (30 °C – 40 °C)
0% - 40% (40 °C – 55 °C)
 |
| Operating Altitude |
 Operating Altitude 2000 m
 |
| Overvoltage category |
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
 |
| Agency Approvals |
 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
 |
| Size |
 203 x 100 x 50 mm (with holster)
 |
| Weight |
 624 g
 |
| Battery life Alkaline |
 Meter use: 1000 hours
Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
 |
| IP Rating |
 IP40
 |
| Voltage DC: |
 Maximum Voltage: 1000 V
 |
| |
 Accuracy: ±(0.09%+2)
 |
| |
 Maximum Resolution: 0.001V
 |
| Voltage AC: |
 Maximum Voltage: 1000 V
 |
| |
 Accuracy: ±(2%+3)
 |
| |
 AC Bandwidth: 5kHz*
*with low pass filter; 3db @ 800 Hz
 |
| |
 Maximum Resolution: 0.1 mV
 |
| Current DC: |
 Maximum Amps: 400mA
 |
| |
 Amps Accuracy: ±(0.2%+2)
 |
| |
 Maximum Resolution: 0.01 mA
 |
| Current AC: |
 Maximum Amps: 400mA
 |
| |
 Amps Accuracy: ±(1.5%+2)*
*1kHz bandwidth
 |
| |
 Maximum Resolution 0.01 mA
 |
| Resistance: |
 Maximum Resistance: 50 MΩ
 |
| |
 Accuracy ±(0.9%+2)
 |
| |
 Maximum Resolution: 0.1Ω
 |
| Capacitance: |
 Maximum Capacitance: 9,999 µF
 |
| |
 Accuracy: ±(1.2%+2)
 |
| |
 Maximum Resolution: 1 nF
 |
| Frequency: |
 Maximum Frequency: 100 kHz
 |
| |
 Accuracy: ±(0.1%+1)
 |
| |
 Maximum Resolution: 0.01 Hz
 |
| Temperature Measurement: |
 40.0 °C to 537 °C
-40.0 °F to 998 °F
excluding probe
 |
| Diode Test: |
 Range: 6 V
 |
| |
 Resolution: 1 mV
 |
| |
 Accuracy: ±(2% + 1)
 |
| Insulation Test: |

 |
| Minimum Test Current @ 1kΩ/V: |
 1mA
 |
| Maximum Resistance per Test Voltage: |
 1000V: 2 GΩ
 |
| Maximum Resolution per Test Voltage: |
 50V: 0.01 MΩ
100V: 0.01 MΩ
250V: 0.1 MΩ
500V: 0.1 MΩ
1000V: 0.1 MΩ
 |
| Accuracy per Test Voltage: |
 50V: ±(3 % + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: ±(1.5 % + 5)
1000V: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
 |