Datasheet: Fluke-1735 |
 |
| Fluke 1735 Three Phase Power Logger 2583398 Description: |
 Fluke 1735 Three Phase Power Logger
(Mfg part No. 2583398) measures most electrical power parameters, harmonics, and captures voltage events. This three phase power logger records power and associated parameters for up to 45 days.
 |
| Fluke 1735 Three Phase Power Logger 2583398 Characteristics: |
| |
 Record power and associated parameters for up to 45 days
 |
| |
 Monitor maximum power demand over user-defined averaging periods
 |
| |
 Prove the benefit of efficiency improvements with energy consumption tests
 |
| |
 Measure harmonic distortion caused by electronic loads
 |
| |
 Improve reliability by capturing voltage dips and swells from load switching
 |
| |
 Easily confirm instrument setup with color display of waveforms and trends
 |
| |
 Measure all three phases and neutral with included 4 flexible current probes
 |
| |
 View graphs and generate reports with included Power Log software
 |
| |
 Compact, rugged design with IP65 case
 |
| |
 600 V CAT III
 |
| |
 Two-year warranty
 |
| Fluke 1735 Three Phase Power Logger 2583398 Applications: |
| |
 Load studies
 |
| |
 Energy assessments
 |
| |
 Harmonics measurements
 |
| |
 Voltage event capture
 |
| Fluke 1735 Three Phase Power Logger 2583398 Specifications: |
| Display |
 ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
 |
| Quality |
 Developed, designed and manufactured according to DIN ISO 9001
 |
| Memory |
 4 MB Flash memory, 3.5 MB for measuring data
 |
| Interface |
 RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
 |
| Sample rate |
 10.24 kHz
 |
| Line frequency |
 50 Hz or 60 Hz, user-selectable, with automatic synchronization
 |
| Power supply |
 NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
 |
| Operation time with battery |
 Typical > 12 hours without backlight and > 6 hours with backlight high
 |
| Dimensions |
 240 mm x 180 mm x 110 mm
 |
| Weight |
 1.7 kg, including battery
 |
| Working temperature range |
 -10 °C to +50 °C
 |
| Storage temperature range |
 -20 °C to +60 °C
 |
| Operating temperature range |
 0 °C to +40 °C
 |
| Reference temperature range |
 23 °C ± 2 °C
 |
| Temperature coefficient |
 ± 0.1 % of the measured value per °C from the reference
 |
| Intrinsic error |
 Refers to reference temperature, maximum deviation is guaranteed for two years
 |
| Operating error |
 Refers to operating temperature range, maximum deviation is guaranteed for two years
 |
| Climatic class |
 C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
 |
| Housing |
 Housing: Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
 |
| Emission |
 IEC/EN 61326-1:1997 class B
 |
| Immunity |
 IEC/EN 61326-1:1997
 |
| Safety |
 IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
 |
| Protection |
 IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
 |