Datasheet: Fluke-120-190-Series |
 |
| Fluke 196CM/003 Medical ScopeMeter Description: |
 Fluke 196CM/003 Medical ScopeMeter are high-performance oscilloscope for the most demanding applications when servicing medical imaging equipment and video systems.

Fluke 196CM/003 Medical ScopeMeter offers measurement capabilities optimized for servicing medical equipment in the following modalities: X-ray, MRI, Nuclear Medicine and Ultrasound. Discontinued product - Replaced by Fluke-190-202/AM/S.
 |
| Fluke 196CM/003 Medical ScopeMeter Applications: |
| |
 Servicing medical imaging equipment and video systems
 |
| |
 X-ray, MRI, Nuclear Medicine and Ultrasound
 |
| Fluke 196CM/003 Medical ScopeMeter Characteristics: |
| |
 Dual input of 100MHz
 |
| |
 Real-time sampling of 1 GS/s
 |
| |
 MAs current-over-time measurement
 |
| |
 Connect-and-View automatic triggering, a full range of manual trigger modes plus external triggering
 |
| |
 Video triggering with line selector for standard and high-resolution video systems
 |
| |
 Includes a 5,000 counts true-rms multimeter and a TrendPlot paperless recorder
 |
| |
 Smart averaging
 |
| |
 Selectable persistence mode
 |
| |
 27,500 points per input record length using ScopeRecord mode
 |
| |
 Automatic capture and replay of 100 screens
 |
| |
 Automatic waveform measurements
 |
| |
 Four hours rechargeable NiMH battery pack
 |
| |
 1,000 V CAT II and 600 V CAT III safety certified
 |
| |
 Up to 1,000 V independently floating isolated inputs
 |
| Includes: |
 BC190/803 Battery Charger/Line Voltage Adapter, BP190 NiMH Battery Pack, VPS200-G Voltage Probe (200 MHz, 10:1), Grey, Vps200-R Voltage Probe (200 MHz, 10:1), Red, TL75 Hard Point Test Lead Set, PM 9080 Serial Interface Adapter/Cable, C190 Hard Case, SCC190EFG FlukeView ScopeMeter Software, cable + Case, User manual (CD-ROM), Getting started booklet
 |
| Includes: |
 MA190 Medical Accessory Kit which includes: 50 ohm BNC feedthrough terminator, in insulated enclosure, to maintain proper termination of test connections during measurement.
50 ohm BNC terminator with 10:1 signal attenuation; keeps test terminal properly loaded while getting optimum signal amplitude to benefit from the instrument’s extended offset range.
1 ohm current shunt for current measurements, in insulated enclosure.
Safety-designed BNC cable, 1.5 m (5 ft), with plastic connectors for safe connection to test terminals even when not at ground potential.
Insulated BNC(f) to 4 mm banana plug adapter.
Dual 4 mm banana receptacles (1 red, 1 black).
MS190 Medical Software Extension Kit
 |
| Warranty |
 3 years on main instrument, 1 year on the standard accessories
 |
| Fluke 196CM/003 Medical ScopeMeter Specifications: |
| Bandwidth |
 100 MHz
 |
| Max. real time sample rate |
 1.0 GS/s
 |
| Display |
 144 mm Full Color LCD
 |
| Digital Persistence |
 Yes, gives analog oscilloscope like waveform decay (user selectable)
 |
| Envelope mode |
 Yes
 |
| Waveform Compare |
 Visual Reference and Automatic ‘Pass/Fail’ testing
 |
| Max. record length… in Scope mode: |
 1200 points per input channel
 |
| €¦ in ScopeRecord mode: |
 27,000 points per input or more (5 ms/div…2 min/div.)
 |
| Number of inputs |
 2 plus external / DMM input, all isolated from each other and from ground
 |
| Number of digitizers |
 2
 |
| Independently floating isolated inputs |
 Up to 1000 V between inputs, references and ground
 |
| Input sensitivity |
 2 mV/div. … 100 V/div.
 |
| Glitch capture |
 Up to 3 ns using Pulse Width triggering; 50 ns peak detect at 5 ms/div. to 1 min/div.
 |
| Timebase range in Scope mode |
 5 ns/div to 2 min/div
 |
| Trigger types |
 Connect-and-View®, Free Run, Single Shot, Edge, Delay, Video Frame, Video line, Selectable pulse width and External
 |
| Scope Measurements |
 7 cursors measurements, 30 automatic measurements
 |
| Waveform Mathematics |
 A + B, A – B, A x B, A versus B (X-Y-mode, giving Lissajous diagrams)
 |
| Scope-Record Trigger modes |
 Start on Trigger, Stop on Trigger
 |
| Capture last 100 screens |
 Automatic, with Replay capability
 |
| Dual input |
 TrendPlot Yes, with Cursors and Zoom
 |
| Memory for screens and set-ups |
 10 screens with set-up; 5 more memories are made available upon registration of the ScopeMeter
 |
| Memory for recordings |
 Two, each can store 100 scope screens, a ScopeRecord or a TrendPlot
 |
| True RMS multimeter |
 5000 counts, Volts, Amps, Ohms, Continuity, Diode, Temp
 |
| Safety certified (EN61010-1) |
 1000 V CAT II / 600 V CAT III (instrument and included accessories)
 |
| Battery (installed) |
 4 hr Ni-MH BP190
 |
| Line power |
 Adapter/battery-charger included
 |
| PC and Printer interface |
 Using optional Optically Isolated RS-232 adapter/cable
 |
| Dimensions |
 25.6 x 16.9 x 6.4 cm (10.1 x 6.7 x 2.5 inch)
 |
| Weight |
 2 kg
 |
| Oscilloscope Mode: |

 |
| Display and acquisition |
 Channels displayed: Input A, input B, dual channel
Display modes: Smart averaging, normal averaging, selectable persistence, invert, replay
Smart averaging displays averaged curve; incidental waveforms that differ too much from the average curve are displayed but do not contribute to the averaged curve
Averaging factor: Selectable: 2x, 4x, 8x, 64x or off
Selectable persistance decay time: Short, medium, infinite or off; can be used with dots only display or with dot join mode
 |
| Trigger and delay - Video Triggering |
 Interlaced video: NTSC, PAL, PALplus, SECAM. Selects field 1, field 2, lines or on user selected line from a frame
Non-interlaced video: For line counts up to 2800 lines per frame and and video scan rates up to 65 kHz; triggers on fields, on lines or on user-selected line
 |
| Cursor measurements |
 Dual vertical lines: Time between cursors, voltage between markers, 1/T (in Hz), mVs, mAs
 |
| Zoom |
 Horizontal zoom: Up to 8x
Vertical zoom: Using position control (offset) and vertical sensitivity
 |
| Offset range |
 Max. offset for viewing positive-going signals: 16 divisions for input sensitivity settings 5…50 mV/div (50…500 mV/div. when using 10:1 probe or TA190-50R); 8 divisions for all other vertical sensitivity settings
Max. offset for viewing negative-going signals: 8 divisions for all vertical sensitivity settings
 |

Need Technical Advise? Please Call: 602-795-4033