Datasheet: Fluke-TI55FT-20-54 |
 |
| Fluke TI55FT-20-54 IR FlexCam Thermal Imager 2649117 Description: |
 Fluke TI55FT-20-54 IR FlexCam Thermal Imager with IR-Fusion (Mfg. part no. 2649117) is the professional’s choice when demanding the highest sensitivity and the best images.

This IR Flexcam thermal imager features the innovative IR-Fusion technology which captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. Free ground shipping within continental US.
 |
| Fluke TI55FT-20-54 IR FlexCam Thermal Imager 2649117 Applications: |
| |
 Predictive maintenance – Identify electrical and mechanical problems before they cause failure
 |
| |
 Power/utilities – Real-time analysis of substations, transmission lines and equipment
 |
| |
 Research and development – Quantify heat patterns to improve product designs
 |
| |
 Process monitoring – Real-time observation to ensure efficient and safe operation
 |
| |
 Electronic design – Close up circuit board analysis
 |
| Fluke TI55FT-20-54 IR FlexCam Thermal Imager 2649117 Characteristics: |
| |
 High resolution, low noise VOx detector for high quality images
 |
| |
 Temperature range to cover broad industrial applications
 |
| |
 High thermal sensitivity for viewing even the smallest temperature differences
 |
| |
 180º articulating flexible lens to view images in every situation
 |
| |
 Large 5" high contrast color LCD for a clear picture independent of lighting conditions
 |
| |
 Fully radiometric for detailed temperature analysis and tracking
 |
| |
 SmartFocus for best image quality and accurate temperature measurements
 |
| |
 Windows CE based menu structure for ease of use
 |
| |
 Personalized instrument set-up for multiple use
 |
| |
 CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
 |
| |
 SmartView reporting and analysis software included
 |
| |
 AutoCapture for making intermittent problems visible
 |
| |
 On-board analysis functions
 |
| |
 User defined text annotations for simplified reporting
 |
| |
 Built-in visible light (digital) camera
 |
| |
 Laser pointer for easy targeting
 |
| |
 Flash and torch light for high quality images in dark environments
 |
| |
 IR/Visible Alarm function
 |
| Warranty |
 2 year warranty
 |
| Includes: |
 Heavy duty carrying case, 2 rechargeable battery packs, Battery charger, Video cable, 512 MB compact flash card, Compact flash card reader and USB cable, Neck strap, SmartView reporting and analysis software on CD, User manual on CD, AC adapter and Calibration certificate
 |
| Fluke TI55FT-20-54 IR FlexCam Thermal Imager 2649117 Specifications: |
| Imaging performance |
 Thermal Field of view (FOV): 20 mm lens 23° x 17° FOV
54 mm lens 9° x 6°
Spatial resolution (IFOV): 1.30 mrad
Min focus distance: 0.15 m
Thermal sensitivity (NETD): ≤ 0.05°C (50 mK)at 30°C Detector data acquisition / Image frequency: 60 Hz
Focus: SmartFocus; one finger continuous focus
IR digital zoom: 2x, 4x, 8x
Detector type: 160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
Detector type: 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer with 25 micron pitch
Spectral band: 8 µm to 14 µm
Digital image enhancement: Automatic full-time enhanced
On-camera operating modes: Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture
Visible light camera: 1280 x 1024 pixels, full color
Visible light digital zoom: 2x, 4x
 |
| Temperature measurement |
 Calibrated temperature range: minus 20˚C to 600˚C (minus 4 to 1122 ºF) in 3 ranges
Range 1: minus 20˚C to 100˚C (minus 4 to 212ºF)
Range 2: minus 20˚C to 350˚C ( minus 4 to 662ºF)
Range 3: 250 °C to 600 °C (482 to 1112 ºF)
Accuracy: plus/minus 2°C or 2 per cent (whichever is greater)
Measurement modes: Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below
Emissivity correction: 0.1 to 1.0 (0.01 increments)
 |
| Image presentation |
 Digital display: 5 inch large high-resolution digital display
LCD backlight: Sunlight readable color LCD
Video output: RS170 EIA/NTSC or CCIR/PAL composite video
Palettes: Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
 |
| Image and data storage |
 Storage medium: Compact flash card stores over 1000 IR images (1 GB card standard)
File formats supported: 14 bit measurement data included. Exportable JPEG, BMP, PNG, GIF, TIFF.
 |
| Interfaces and software |
 Interface: Compact flash card reader included
Software: SmartView; Full analysis and reporting software included
 |
| Laser |
 Classification: Class II
Laser targeting: Laser dot visible on screen when blending thermal and visible image
 |
| Controls and adjustments |
 Set-up controls: Date/time, temperature units C/F/K, language, scale, LCD intensity (high/normal/low)
Image controls: Level, span, auto adjust (continuous/manual)
On-screen indicators: Battery status, target emissivity, background temperature and real time clock
 |
| Battery type |
 Li-Ion smart battery, rechargeable, field-replaceable
 |
| Battery operating time |
 3 hours continuous operation (2 hours with IR-Fusion engaged)
 |
| Battery charging |
 2 bay intelligent charger powered via AC outlet
 |
| Power saving |
 Automatic shutdown and sleep modes (user specified)
 |
| Operating temperature |
 Minus 10°C to plus 50°C (14°F to 122°F)
 |
| Storage temperature |
 Minus 40°C to plus 70°C (minus 40°F to 158°F)
 |
| Relative humidity |
 Operating and storage 10 per cent to 95 per cent, non-condensing
 |
| Water and dust resistant |
 IP54
 |
| Weight (including batteries) |
 1.95 kg (4.3 lbs)
 |
| Camera size (HxWxD) |
 162 x 262 x 101 mm (6.5 inches x 10.5 inches x 4.0 inches)
 |
| AC operation |
 AC adapter 110/220 VAC, 50/60 Hz
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |