| Datasheet: |
 |
| Greenlee 560XL Fiber Optic Power Meter Description: |
 Greenlee 560XL Fiber Optic Power Meter has multi-wavelength storage - store and recall reference power levels for faster,more efficient measurements. This fiber optic power meter has a Snap-On connector interface adapts to FC, SC and ST connectors.
 |
| Greenlee 560XL Fiber Optic Power Meter Characteristics: |
| |
 Easy to use - three buttons control all functions.
 |
| |
 Loss measurements in (dB); power measurements in (dBm).
 |
| |
 0.01dB measurement resolution.
 |
| |
 Multi-wavelength storage - store and recall reference power levels for faster,more efficient measurements.
 |
| |
 Snap-On connector interface adapts to FC, SC and ST connectors.
 |
| |
 Long battery life.
 |
| |
 User selectable auto shut-off.
 |
| |
 Rugged and splash-proof.
 |
| |
 Economically priced.
 |
| Greenlee 560XL Fiber Optic Power Meter Specifications: |
| Calibration Wavelengths |
 850nm, 1300nm,
1310nm and 1550nm
 |
| Power Range |
 -3 dBm to -60 dBm
 |
| Accuracy |
 ± 0.25dB
 |
| Linearity |
 +3dBm to -3dBm 0.5dB
-3dBm to -50dBm ±0.05dB
-50dBm to -60dBm ±0.5dB
 |
| Resolution |
 0.01dB
 |
| Power Requirements |
 Two AA size 1.5V batteries
(approx. 100 hours continuous operation)
 |
| Connector interface |
 FC, SC or ST
 |
| Operating temperature |
 -15° C to +55° C
 |
| Storage temperature |
 -35° C to +70° C
 |
| Humidity |
 0 to 95% non-condensing
 |
| Dimensions |
 7.2 x 14.2 x 3.5 cm (2.8 x 5.6 x 1.4 in.)
 |
| Weight |
 241g (8.5 oz.)
 |
| CE |
 EN61010; EN50081-1: 1992; EN55011,
Group 1, Class A EN50082-1:
1992 IEC 801-2, -3, -4
 |