Datasheet: Protek-6025C |
 |
| Protek 6025C Analog Oscilloscope 25MHz Description: |
 Protek 6025C Analog Oscilloscope 25MHz tests resistors, inductors and capacitors. This analog oscilloscope features an alternate trigger for a stable display of unrelated signals. Free ground shipping within continental USA.
 |
| Protek 6025C Analog Oscilloscope 25MHz Characteristics: |
| |
 Tests Resistors, Inductors and Capacitors
 |
| |
 Alternate trigger for a stable display of unrelated signals
 |
| |
 25MHz Vertical Bandwidth (-3dB)
 |
| |
 X10 Horizontal Magnification
 |
| |
 Internal Sync separator circuit for stable triggering of video signals
 |
| |
 Light weight and low power consumption
 |
| |
 High brightness CRT with internal graticule
 |
| |
 X-Y operation
 |
| Accessories: |
 Operating manual, AC line cord, (2) x1/x10 probes and Test cable
 |
| Protek 6025C Analog Oscilloscope 25MHz Specifications: |
| Vertical Amplifer : |

 |
| Ch1 and Ch2 |
 Sensitivity: 5 mV/Div to 5V/Div in 10 steps (1-2-5 sequence)
Accuracy: ±3%
Bandwidth: (-3dB) DC: 0 to 20MHz AC: 10Hz to 25 MHz
Rise Time: <14.0nS
 |
| Input Impedance |
 Resistance: 1MΩ +- 5 percent;
Capacitance: 25pF +- 5pF
 |
| Input Coupling |
 AC, DC GND
 |
| Display Modes |
 Ch1, Ch2, ALT, Chop, ADD, X-Y
 |
| Invert Channel |
 Ch2
 |
| Maximum Input Volts |
 400V DC (DC or AC p-p)
 |
| Horizontal Sweep: |

 |
| Sweep Times |
 200nS/Div to 0.5 Sec/ Div in 20 steps (1-2-5 seq); (x10 Mag: 20nS/Div to 50mS/Div)
 |
| Accuracy |
 +- 3% (+- 5% X10 MAG)
 |
| Sweep Modes |
 Normal, X-Y
 |
| Triggering: |

 |
| Trigger Source |
 Ch1, Ch2, ALT, LINE and EXT
 |
| Trigger Modes |
 Auto, Norm, TV- V, TV-H
 |
| Trigger Slope |
 Positive or negative adjustable levels
 |
| Trigger Coupling |
 AC
 |
| Trigger Sensitivity |
 Int: 20Hz to 2 MHz: 0.5Div 2MHz to 25MHz: 1.5 Div
TV: INt: 1 Div.; EXT: 1V
ALT: 20Hz to 2MHz: 2.0Div 2MHz to 25MHz: 3.0 Div
Ext:20Hz to 2MHz: 200mV 2MHz to 25MHz: 800mV
 |
| Ext.Trigger Input: |

 |
| Impedance |
 1MΩ +- 5% +25pF Capacitance
 |
| Max. Input Volts |
 400V (DC + AC peak)
 |
| X-Y mode: |

 |
| Inputs |
 X-Axis: Ch1, Y-axis Ch2
 |
| Sensitivity |
 5 mV/Div to 5V/Div in 10 steps (1-2-5 sequence)
 |
| Accuracy |
 +- 4 percent
 |
| Frequency Response |
 (-3dB) DC to = 500KHz
 |
| Phase Difference |
 < 3 from DC to 50KHz
 |
| Component Checker: |

 |
| Test Voltage |
 Approx. 4.5V RMS open circuit
 |
| Test Current |
 6.6mA Max short circuit
 |
| Test Frequency |
 60Hz
 |
| Calibrator Signal: |

 |
| Waveform |
 Square wave
 |
| Frequency |
 1KHz +- 2%
 |
| CRT: |

 |
| Size |
 8cm x 10cm
 |
| Acceleration Volts |
 2KV
 |
| General Specifications: |

 |
| Power Requirements |
 AC input Volts: 120V or 220V
 |
| Frequency |
 50/60Hz
 |
| Power Consumption |
 35W
 |
| Operating Temperature |
 0 to 40 C (32 F to 104 F)
 |
| Amplitude |
 2V +- 2 percent p-p
 |
| Dimensions |
 12.5"(W) x 5.9"(H) x 18.0"(D)
 |
| Weight |
 17 lbs
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |