| Datasheet: |
 |
| Protek 820FC 20 MHz Hand Held Digital Oscilloscope Description: |
 Protek 820FC 20 MHz Hand Held Digital Oscilloscope with Flash USB Port and LCD, high resolution color monitor is a Protek 20MHz Hand-Held DSO-DMM. This Protek oscilloscope has USB Flash Memory as well as self test and self calibration. Free ground shipping within continental USA.
 |
| Protek 820FC 20 MHz Hand Held Digital Oscilloscope Characteristics: |
| |
 High Resolution 320x 240 pixel Monochrome LCD
 |
| |
 USB port,Software and cable included
 |
| |
 10 waveforms and setups may be stored and recalled
 |
| |
 125KB record length for each channel
 |
| |
 Help menu
 |
| |
 20 automatic waveform Measurements
 |
| |
 200MS-s
 |
| |
 Built in High accuracy 6000 count True RMS DMM
 |
| |
 USB Flash Memory
 |
| |
 20Mhz bandwidth
 |
| |
 Edge-Pulse width, TV-Pattern and Delay trigger modes
 |
| |
 Optional Acessaries- Carrying Bag , Spare NiMH Rechargeable Battery Pack , 600 Amp Current Probe
 |
| Protek 820FC 20 MHz Hand Held Digital Oscilloscope Specifications: |
| Vertical |
 No. Inputs- 2;
Analog Bandwidth 20MHz;
Rise Time < 17.5ns;
Sensitivity 5mV to100V-div (in a 1,2,5 sequence);
Resolution 8 bit;
Offset 5 div from the center;
Vertical Accuracy +- 3 percent,
Input Impedance 1MW 1 percent;
20pF 1.3pF;
Max. Input Voltage 300V DC or AC peak;
Probe Attenuation x1 and x10
 |
| Horizontal |
 Sweep Rate 50n-Div to 50s-Div;
Time Base Accuracy +- 0.01 percent
 |
| Acquisition System |
 Acquisition Modes Sample, Peak detect, Envelope, Average
Sample Rate 200Ms-S
Sample Rate Accuracy 100ppm
Record Length 125KB-Channel
Waveform Interpolation Dot, Linear, Sine, and Pulse
Peak Detect 10ns minimum
Averages 2 to 256
 |
| Trigger |
 Sensitivity 0.5 Div (DC to 5MHz);
Trigger Types Edge, Pulse width, Video;
Coupling AC, DC HF-Reject, LF-Reject, Noise Reject
Modes Normal, Single, Roll, Auto
Trigger Level Range �20 Div from the center of the screen
Trigger Level Accuracy +- 0.4 Div
Trigger Source CHA and CHB
 |
| Video Trigger |
 Video Trigger sensitivity 0.7 Div;
Video Type NTSC, PAL, Secam
 |
| Measurements |
 Types P-P, Max, Amplitude, Top, Base, Pos-Neg over shoot, Pre-shoot, RMS, Mean, One cycle mean, Freq., Period, Width, Duty cycle, Rise-Fall time, Delay and Phase shift;
Cursors DV, DT;
Weighting Rectangular, Hamming, Hanning and Blackman-Harris;
Amplitude Display 1, 2, 5, 10dB-Div;
Maximum Frequency 1.25GHz;
Memory 10 waveforms and settings saved and recalled
 |
| DC Volts |
 Range 600mV to 1000V;
Accuracy +- (0.3 percent + 10d);
Best Resolution 100 V;
Impedance 10MW;
Overload protection 1000VDC or AC peak
 |
| AC Volts |
 Range 6V to 600V;
Accuracy +- (0.75 percent + 10d) 50Hz to 1KHz
+- (2.0 percent + 10d) 1KHz to 30KHz;
Best Resolution 1mV;
Impedance 10MW;
Overload protection 1000VDC or AC peak
 |
| Resistance |
 Range 600W to 60MW;
Accuracy +- (0.5 percent + 10d);
Best Resolution 100mW;
Overload Protection 250V DC or AC peak
 |
| Capacitance |
 Range 60nF to 300 F;
Accuracy +- (2.0 percent + 10d)
 |
| Other measurements |
 Diode Test Accuracy +- 2 per cent;
Continuity Buzzer will sound < 60W
dBm with reference impedances of 2, 4, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1K or 1.2KW
High Current To 600A with external current Clamp
Temperature (with Probe) To 600 C (1112 F)
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |