| Datasheet: |
 |
| Schonstedt GA-52Cx Magnetic Locator Description: |
 Schonstedt GA-52Cx Magnetic Locator detect the magnetic field of iron and steel objects and energized power lines. It provide audio detection signals that peak in frequency when the locator's tip is held directly over the target.

Schonstedt's underground magnetic locators have been setting the standards for reliability and dependability for over 30 years. They are designed to withstand the rigors of daily on-site usage and a wide range of environmental conditions. In fact, the Model GA-52Cx is so rugged and dependable it's backed by a 7-year warranty.

Schondtedt GA-52Cx magnetic locator is designed for one-hand operations, the On/Off-Sensitivity and Volume controls are located on the underside of the cover on both locators. This provides easy access, protects the knobs and contributes to their overall ruggedness and dependability.
 |
| Schonstedt GA-52Cx Magnetic Locator Characteristics: |
| Warranty: |
 Seven Year Warranty
 |
| |
 Enhanced target definition
 |
| |
 Unsurpassed detection range
 |
| |
 Piezoelectric speaker
 |
| |
 Clear, sharp, detection signal pinpoints the targe
 |
| |
 Five individual sensitivity settings
 |
| |
 No response to aluminum, brass, or copper
 |
| |
 Ease of operation reduces search time
with experience, user can distinguish between small pieces of scrap iron and actual targets
 |
| |
 40-hours operation (intermittent usage) on two economical 9-volt batteries
 |
| |
 Modular construction
 |
| |
 High performance component
 |
| |
 Weather protected controls
 |
| |
 Rugged lightweight case
 |
| |
 Patented HeliFlux sensors
 |
| |
 Y2K Compliant
 |
| Magnetic Locating Tips |

 |
| Magnetic Locators and Circuits: |

 |
| |
 Magnetic locator GA-52Cx can be used to determine if a circuit is active, such as an automobile rear window defogger grid, or a radiant heat panel.
 |
| |
 Set the sensitivity of the locator on high, and place the instrument sensor (the tip) near the window grid, ceiling panel, etc.
 |
| |
 Just listen for a change in the output tone when the circuit is activated by its on/off control.
 |
| Energized Power Lines: |
 A burbling sound on the GA-52Cx indicates the presence of an energized power line.
 |
| Schonstedt GA-52Cx Magnetic Locator Specifications: |
| Input Power |
 Two alkaline 9-volt batteries
 |
| Battery Life |
 40 hours (intermittent usage)
 |
| Output |
 Approximately 40 Hz audio tone on speaker. Tone frequency increases or decreases with gradient-field intensity.
 |
| Weight |
 Approximately 2.5lb. (1.13 kg.)
 |
| Operating Temp |
 -13oF to 140oF (-25oC to 60oC)
 |
| Overall Length |
 42.3 in. (107.4 cm)
 |
| Waterproof Length |
 34.5 in. (87.6 cm)
 |
| Nominal Sensor Spacing |
 20 in. (50.8 cm)
 |
| Construction |
 Modular, all solid state
 |
| Schonstedt GA-52Cx Magnetic Locator Applications: |
| |
 Detects the magnetic field of iron and steel objects and energized power lines
 |
| |
 Provides audio detection signals that peak in frequency when the locator’s tip is held directly over the target
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |