Datasheet: TPI-1010 |
 |
| TPI 1010 Indoor Air Quality IAQ Meter Description: |
 TPI 1010 Indoor Air Quality IAQ Meter features Calculate percent outside air to maintain acceptable CO2 levels in buildings and work spaces, Measure and display Carbon Dioxde(CO2) and Carbon Monoxide, Measure ambient air temperature, Measure relative humidity, dew, point and wet bulb, Log up to 4,000 readings in 1 second to 23 hour 59 minutes intervals, Download to a computer using the A368 USB cable.
 |
| TPI 1010 Indoor Air Quality IAQ Meter Applications: |
| |
 Check ambient CO and CO2 levels in work and living spaces
 |
| |
 Monitor results of air control systems
 |
| |
 Ambient air temperature and humidity
 |
| |
 Test dew point and wet bulb humidity
 |
| TPI 1010 Indoor Air Quality IAQ Meter Characteristics: |
| |
 Calculate percent outside air to maintain acceptable CO2 levels in buildings and work spaces
 |
| |
 Measure and display Carbon Dioxde (CO2) and Carbon Monoxide
 |
| |
 Measure ambient air temperature
 |
| |
 Measure relative humidity, dew point and wet bulb
 |
| |
 Log up to 4,000 readings in 1 second to 23 hour 59 minutes intervals
 |
| |
 Download to a computer using the A368 USB cable
 |
| TPI 1010 Indoor Air Quality IAQ Meter Specifications: |
| Function Range Accuracy |

 |
| CO2 |
 0 to 5000ppm 50 degrees F to 104 degrees F: ±3 percent of rdg+75ppm <50 degrees F, >104 degrees F: ±5 percent of rdg+75ppm
 |
| Temperature |
 -5 degrees F to 140 degrees F -20 degrees C to 60 degrees C ±2 degrees F ±1 degrees C
 |
| Dew Point Temperature |
 -47 degrees F to 135 degrees F -44 degrees C to 57 degrees C Calculation
 |
| Wet Bulb Temperature |
 3 degrees F to 135 degrees F -16 degrees C to 57 degrees C Calculation
 |
| Relative Humidity |
 5 percent to 95 percent ±2 percent RH
 |
| CO |
 0 to 500ppm ±3ppm or ±5 percent of rdg whichever is greater percent Outside Air 0 to 100 percent Calculation
 |
| Data Logging: |
 Up to 4,000 samples 1 sec to 23hr 59min interval
 |
| Display Type: |
 3 line with annunciators and backlight
 |
| CO Alarm: |
 Audible and visual, selectable level (factory default 30ppm)
 |
| Operating Temperature & Humidity |

 |
| CO and CO2: |
 14 degrees F to 122 degrees F (-10 degrees C to 50 degrees C)
 |
| All Other Function: |
 -4 degrees F to 140 degrees F (-20 degrees C to 60 degrees C)
 |
| Humidity |
 15 to 95 percent non-condensing
 |
| Storage Temperature: |
 -4 degrees F to 140 degrees F (-20 degrees C to 60 degrees C)
 |
| Power supply |
 3 AA cell alkaline batteries ( 4.5V)
AC/DC adapter 5Vout (Center positive)
 |
| Battery Life: |
 40 hours typical without backlight
 |
| Output: |
 Serial output via USB connection
 |

Need Technical Advise? Please Call: 602-795-4033