Datasheet: UEI-C127-Oilkit |
 |
| UEi C127-OILKIT Combustion Gas Analyzer Description: |
 UEi C127-OILKIT Combustion Gas Analyzer (with NOx and printer and smoke tester) measures Flue temperature, oxygen, carbon monoxide (CO),
Differential, ambient carbon monoxide (CO), and differential pressure, and Nitric Oxide (NOx).

UEi C127-OILKIT Combustion Analyzer is an effective and affordable way to measure combustion efficiency when installing or maintaining oil-burning appliances. Made in UK. Free ground shipping within continental US.
 |
| UEi C127-OILKIT Combustion Gas Analyzer Applications: |
| |
 Measure combustion efficiency when installing or maintaining oil-burning appliances
 |
| UEi C127-OILKIT Combustion Gas Analyzer Characteristics: |
| UEi C127-OILKIT Combustion Gas Analyzer Features: |
| |
 Smoke Pump Test Kit
 |
| |
 Measures Flue temperature, oxygen, carbon monoxide (CO), Differential, ambient carbon monoxide (CO), and differential pressure, & Nitric Oxide (NOx)
 |
| |
 Calculates carbon dioxide, gross/net efficiency, excess air, CO air free
 |
| |
 Worklight
 |
| |
 Unique DMM style rotary selector
 |
| |
 Protective boot w/integral magnet
 |
| |
 Real time clock
 |
| |
 CO readings to 1 ppm
 |
| |
 Large 4 line back-lit display
 |
| |
 Infrared printer port
 |
| |
 User programmable header
 |
| |
 179 memory position
 |
| |
 User customizable parameters view
 |
| |
 Individual report printouts
 |
| |
 Infrared printer por
 |
| Warranty |
 Three year limited warranty (2 year warranty on sensor)
 |
| Kit includes: |
 Eagle 3 (C127) Combustion Analyzer
 |
| |
 KMIRP2 Infrared Thermal Printer
 |
| |
 Flue Probe
 |
| |
 (2) K-Type Temperature Probe
 |
| |
 (2) Static pressure hoses
 |
| |
 True draft probe
 |
| |
 Gas pressure probe
 |
| |
 AACA4 AC adapter
 |
| |
 AC509 Hard Carrying Case
 |
| |
 Particle filter
 |
| |
 Thermal printer paper roll
 |
| |
 Quick start manual & owners guide
 |
| UEi C127-OILKIT Combustion Gas Analyzer Specifications: |
| Inlet Temp Range |
 20 ~ 2400 F / -29 ~ 1315 C
 |
| Flue Temp Range |
 20 ~ 2400 F / -29 ~ 1315 C
 |
| Inlet Temp Range (Ambient) |
 32 ~ 112 F / 0 ~ 50 C
 |
| Net Temp (ΔT) |
 20 ~ 2400 F / -29 ~ 1315 C
 |
| Resolution |
 0.1 F/C
 |
| Flue (T1, Inlet T2, & Net ΔT) Accuracy |
 +- [0.3% rdg +3.6 F(2 C)]
 |
| Inlet Temp Ambient Accuracy |
 +- [0.3% rdg +1.8 F(1 C)]
 |
| Gas Measurement: |

 |
| Oxygen |
 0 ~ 21%
 |
| O2 Resolution/Accuracy |
 0.1% / +- 0.2%
 |
| Carbon Monoxide |
 0 ~ 4000 ppm
 |
| CO Resolution/Accuracy |
 1 ppm/+- 10 ppm < 100 ppm
+- 5% reading
 |
| Carbon Dioxide |
 0 ~ 30%
 |
| CO2 Resolution/Accuracy |
 1.0%/+- 0.3% reading
 |
| Efficiency |
 0 ~ 99.9%
 |
| Efficiency Resolution/Accuracy |
 0.1%/+- 1.0% reading
 |
| Excess Air |
 0 ~ 250%
 |
| Excess Air Resolution/Accuracy |
 0.1%/+- 0.2% reading
 |
| CO/CO2 |
 0 ~ 0.999%
 |
| CO/CO2 Resolution/Accuracy |
 0.0001%/+- 5% reading
 |
| Nitric Oxide |
 1 ppm/ 2 ppm < 30 ppm
 |
| Nitric Oxide Resolution/Accuracy |
 +- 5 ppm > 30 ppm
 |
| Pressure (Differential) |
 Range: 0.001mBar/+- 0.005mBar +- 0.002 wg
0.001mBar/+- 0.03mBar +- 0.01 wg
0.01mBar/�3% reading
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |