| Datasheet: |
 |
| Yellow Jacket 40812 Digital Refrigeration System Analyzer Description: |
 Yellow Jacket 40812 Digital Refrigeration System Analyzer profiles 23 common refrigerants:
R-12, 22, 134a, 290, 401A, 401B, 402A, 402B, 404A, 406A, 407C, 408A, 409A, 410A, 414B, 416A, 417A, 420A, 422A, 502, 507, 508B, 600A (Upgradeable probe for new refrigerants). This Digital Refrigeration System Analyzer features integrated temperature probe for automatic superheat and subcooling readings.
 |
| Yellow Jacket 40812 Digital Refrigeration System Analyzer Features: |
| |
 Profiles 23 common refrigerants:
R-12, 22, 134a, 290, 401A, 401B, 402A, 402B, 404A, 406A, 407C, 408A, 409A, 410A, 414B, 416A, 417A, 420A, 422A, 502, 507, 508B, 600A (Upgradeable probe for new refrigerants)
 |
| |
 Integrated temperature probe for automatic superheat and subcooling readings
 |
| |
 Max and min pressure monitoring for control set-up
 |
| |
 Auto zero key to eliminate manual recalibration
 |
| |
 Vacuum detection in Hg
 |
| |
 Easy-to-read LCD screen with large 3/8" digits
 |
| |
 Rugged case construction with rubber boot to tolerate impact and resist typical oils, acids, and sunlight
 |
| |
 2 year warranty
 |
| |
 Bar graph segments shows changes from digital reading (range of ±2 psi on low side, ±8 psi on high side)
 |
| |
 Digital readings show resolution of 1/4 psi on low side, 1 psi on high side
 |
| |
 Temperature in middle is corresponding bubble and dew points for current pressures
 |
| |
 Temperature, superheat or subcooling shown on lower right (eg. 14°F superheat)
 |
| |
 Titan 4-valve manifold
 |
| Yellow Jacket 40812 Digital Refrigeration System Analyzer Specifications: |
| Pressure accuracy |
 0.5% F.S. ± 1 least significant digit
 |
| Pressure ports |
 Two 1/8" acting as low and high side gauges
 |
| Working pressure |
 Low side: 0-200 psi (1350 kPa, 13.5 bar)
 |
| High side |
 0-550 psi (3790 kPa, 37.9 bar)
 |
| Proof pressure |
 Low side: 600 psi (4100 kPa, 41 bar)
High side: 1500 psi (10300 kPa, 103 bar)
 |
| Temperature sensor range |
 -40° to 250°F (-40° to 125°C)
 |
| Temperature accuracy |
 ±0.9°F (±0.5°C) between 32° to 158°F (0° to 70°C)
 |
| Usage environment |
 Indoor/Outdoor dew, splash and rain resistant; do not immerse in water
 |
| Storage and operational temperature |
 -4° to 122°F (-20° to 50°C)
 |
| Power supply |
 9V (approx. 6 months under normal use)
 |
| Weight |
 1.6 lb. (.725 kg)
 |
| Dimensions |
 6.7" x 4.8" x 2.5" (17 cm x 12.2 cm x 6.4 cm)
 |

Need Technical Advise? Please Call: 602-795-4033
Browse Similar Products |