Main page content
AEMC L404 Four Channel Simple Logger II
2126,29
QVT-2010052512363580642
Electrical
HVAC
Industrial
AEMC L404 Four Channel Simple Logger II logs events via four channels. It is an economical, advanced design data logger recorder that incorporates features and functions that can't be found in data loggers costing 2 to 3 times its price. AEMC L404 Four Channel Simple Logger II stores event data only as the event occurs, and will work with dry contact closure or 0-3 and 0-5VDC logic levels. Internal memory accommodates over 50,000 events--more than enough for most data collection needs. Event measurement scaling is user programmable. Installation is easy in tight locations due to battery operation and compact size and no need for external power. Front panel LEDs give the user a quick status of the logger's state and memory usage. AEMC L404 Four Channel Simple Logger II includes DataView software, which provides real-time viewing of measurement data, even while recording. Standard features also include instrument configuration, data storage and report generation from a pre-defined template, or operator custom-designed.
Features
| Chracteristics: | AEMC L404 Four Channel Simple Logger II |
| 4 input channels | |
| Compatible with dry contact closure or 0-3 and 0-5V DC logic levels | |
| Storage rates are programmable to 8 per second or 1 per day | |
| Up to 50,000 measurements stored in non-volatile memory | |
| Standard, alkaline batteries provide power (included) | |
| Lightweight and compact enough to fit anywhere | |
| Logger status quickly and clearly displayed via 5 LED indicators | |
| Comes complete with DataView |
Specifications
| Specifications: | AEMC L404 Simple Logger II |
| Channels | Four |
| Input Connection | One 8 position removable screw type terminal block |
| Voltage Range | 0 to 5V DC or contact closure |
| Sample Rate | Selectable from 125ms to 1 day |
| Storage Rate | Event triggered (maximum once every 2 sample periods) |
| Storage Modes | Event recording |
| Recording Length | 15 minutes to 8 weeks, programmable using DataView |
| Memory | 50,000 events (512KB). The recorded data is stored in non-volatile memory and retained even if the battery is low or removed |
| Communication | USB 2.0 optically isolated |
| Power Source | 2 x 1.5V AA-cell Alkaline batteries |
| Battery Life | 100 hours to > 45 days (dependent on storage rate/recording length) |
| Dimensions(without removable connector) | 5.06 x 2.75 x 1.28" (129 x 70 x 32mm) |
| Weight (with battery) | 6.4 Oz (180 grams) |
| Case | UL94-V0 |
| Vibration | IEC 68-2-6 (1.5mm, 10 to 55 Hz) |
| Shock | IEC 68-2-27 (30G) |
| Drop | IEC 68-2-32 (1m) |
| Operating Temperature | 14° to 122°F (-10° to 50°C) |
| Storage Temperature | -4° to 140°F (-20° to 60°C) |
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov |