Main page content
The Amprobe AM-530 True-rms Electrical Contractor Multimeter is the multimeter of choice for a professional electrical contractor; it is able to measure and verify voltage amounts in order to connect equipment, perform repairs, identify blown fuses, check continuity of electrical connections, run new wiring, and troubleshoot motors or check transformers. The AM-530 uses true-rms sensing to accurately measure voltage on systems affected by harmonics. It includes a built-in flashlight and probe holder with Voltect non-contact voltage detection. Amprobe AM-530 True-rms Electrical Contractor Multimeter includes a 9V(6F22) battery, test leads, type-K probe, Velcro strap, carrying case, and a user guide.
Features
| Chracteristics: | Amprobe AM-530 TRMS Multimeter for Electrical Contractors |
| Measures Voltage up to 750V ac, and 1000V dc | |
| Measures resistance, frequency, capacitance, and temperature | |
| CAT III 600V, CAT II 1000V safety-rated | |
| True-rms accurate measuring | |
| VolTect non-contact voltage detection | |
| Audible stability beeper | |
| Diode testing capabilities | |
| Data hold button to allow the user to freeze the current reading | |
| Memory stores max/min readings | |
| Relative-zero mode | |
| Built-in flashlight and backlit LCD screen with analog bar graph display | |
| Built-in test lead storage and probe holder | |
| Auto/manual ranging | |
| Auto-off | |
| Low-battery warning |
Specifications
| Specifications: | Amprobe AM-530 True-rms Electrical Contractor Multimeter | |
| Feature | AM-520 | Best Accuracy |
| True-rms | Yes | |
| AC Voltage | 400 mV, 4.000 V, 40.00 V, 400.0 V, 750 V | +/- (1.0 % rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400 V ranges |
| DC Voltage | 400 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V | +/- (0.8% rdg + 1 LSD) @ 4 V to 400 V ranges |
| AC Current | 400.0 µA, 4000 µA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A | +/- (1.2% rdg + 3 LSD) |
| DC Current | 400.0 µA, 4000 µA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A | +/- (1.0% rdg + 2 LSD) |
| Frequency | 10 Hz to 10 MHz | +/- (0.1% rdg + 4 LSD) |
| Resistance | 400.0 O, 4.000 kO, 40.00 kO, 400.0 kO, 4.000 MO, 40.00 MO | +/- (1.0% rdg + 2 LSD) @ 4 kO to 400 kO ranges |
| Capacitance | 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF, 4000 µF | +/- (3.0% rdg + 5 LSD) @ 400 nF to 40 µF ranges |
| Temperature | -40 °F to 1832 °F -40 °C to 1000 °C | +/- (1.8% rdg + 6 °F) @ >32 °F to 212 °F +/- (1.2% rdg + 3 °C) @ >0 °C to 100 °C |
| Number of temperature inputs | Single Thermocouple | |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.