Fluke I400S AC Current Clamp. The Fluke i400s Current Clamp works with instruments measuring ac millivolts. Those instruments need to have standard BNC connector for coupling with i400. Fluke i400s features input impedance of greater than or equal to 1 M ohm in parallel with a maximum of 47 pF. The Current Clamp can also be used with digital multimeters using a BNC-to-banana jack adapter. Mfg part Fluke 2277202. Fluke parts and accessories.
Features
| Companion to your scope or power quality meter to measure up to 400 A AC. | |
| Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating. | |
| Specially designed to offer maximum utility in a compact shape. | |
| Take accurate current readings without breaking the circuit. | |
| Soft non-slippery overmold handle. | |
| Optional PM9081/001 BNC/Banana adapter for DMM's | |
| Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output. | |
| Max. conductor Ø 32 mm. |
Specifications
| Nominal current range: | 40 A Range 0.5 A to 40 A 400 A Range 5 A to 400 A |
| Basic accuracy: | 40 A Range 2 percent + 0.015 A (45-400 Hz) 400 A Range 2 percent + 0.04 A (45-400 Hz) |
| Phase Shift: | 40 A Range 0.5 to 1 A Unspecified 1 A to 5 A 4 degrees 5 A to 10 A 3 degrees 10 A to 20 A 3 degrees 20 A to 40 A 2 degrees 40 A to 400 A NA 400 A Range 0.5 to 1 A NA 1 A to 5 A NA 5 A to 10 A Unspecified 10 A to 20 A 2 degrees 20 A to 40 A 2 degrees 40 A to 400 A 1.5 degrees |
| Typical Bandwidth: | 40 A Range 5 Hz - 10 kHz 400 A Range 5 Hz - 10 kHz |
| Output level(s): | 40 A Range 10 mV/A 400 A Range 1 mV/A |
| Crest Factor: | 40 A Range ≤ 3 400 A Range ≤ 3 to 300 A ≤ 2.5 to 400 A |
| Safety Specifications | |
| Safety | CAT IV 600 V, CAT III, 1000 V |
| Maximum Non-Destructive Current | 1000 V AC |
| Mechanical and General Specifications | |
| Warranty | 1 year |
| Maximum conductor size | 32 mm (1.25 inches) |
| Output cable length | 2.5 m (8.2 ft) |
| BNC Adapter | Yes |
| Dimensions | 150 x 70 x 30 mm |
| Weight | 114 g |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.