Temperature
|
Temperature Range
| -20 °C to +250 °C (-4 °F to + 482 °F)
|
Accuracy
| ± 5 °C or 5 % (whichever is greater)
|
Imaging Performance
|
Field of View
| 23° x 17°
|
Spatial Resolution (IFOV)
| 2.5 mRad
|
Minimum Focus Distance
| Thermal lens: 15 cm (6 in)
|
Focus | Manual |
Frequency
| 9 Hz |
Resolution | 160 X 120 focal plane array, uncooled microbolometer |
Infrared Lens Type | 20 mm F = 0.8 lens |
Thermal Sensitivity (NETD) | ≤ 0.2 °C at 30 °C (200 mK) |
Infrared Spectral Band | 7.5 μm to 14 μm |
Image Presentation |
Palettes
| Ironbow, blue-red, high contrast, grey
|
Level and Span
| Smooth auto-scaling and manual scaling of level and span
|
Minimum span (in manual mode) | 5 °C (9 °F) |
Minimum span (in auto mode) | 10 °C (18 °F) |
Image and Data Storage |
Storage Medium | SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR or 3000 basic (.bmp) IR images) |
File Formats | Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files |
Export file formats w/SmartView® software | JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF |
General Specifications |
Temperature - Operating | -10 °C to 50 °C (14 °F to 122 °F) |
Temperature - Storage | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Display | 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) |
Controls and Adjustments | User selectable temperature scale (°C/°F) Language selection Time/Date set
|
Software | SmartView® full analysis and reporting software included |
Battery | Internal rechargeable battery pack (included) |
Battery Life | Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery Charge Time (using ac adapter/charger and dc car charger) | Two hours for full charge |
AC Operation/Charging | AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. |
Power Saving | Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity |
Safety Standards | CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2 |
Electromagnetic Compatibility
| EMC directive: EN61326-1 C-Tick: IEC/EN 61326 US FCC: CFR 47, Part 15 Class A |
Vibration | 2 G, IEC 68-2-29 |
Shock | 25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides} |
Dimensions (HxWxL) | 0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in) |
Weight | 1.2 kg (2.65 lb) |
IP rating
| IP54 |
Warranty | Two-years |
Calibration cycle | Two-years (assumes normal operation and normal aging) |