Specifications: | Fluke TiS Thermal Imager Thermal Imaging Scanner
|
Temperature
|
Temperature Range
| -20 °C to +100 °C (-4 °F to +212 °F)
|
Temperature measurement accuracy
| ± 5 °C or 5 % (at 25 °C nominal, whichever is greater)
|
Imaging performance
|
Frequency
| 9 Hz refresh rate
|
Resolution
| 120 X 120 Focal Plane Array, uncooled microbolometer |
Thermal Sensitivity (NETD)
| ≤ 0.1 °C at 30 °C target temp. (100 mK)
|
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Standard infrared lens type | Field of view: 17° x 17° Spatial resolution: (IFOV) 2.50 mRad Minimum focus distance: 15 cm (approx. 6 in) |
Focus mechanism | Versatile, one-handed manual focus |
Image presentation |
Palettes | Ironbow, Blue-Red, Grayscale |
Level and span | Smooth auto-scaling and lock of level and span |
Minimum span (in auto mode) | 5 °C (9 °F) |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Storage medium
| SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR images annotations, or 3000 basic bitmap (.bmp) images, transferrable to PC via included multi-format USB card reader |
File formats | Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometic bitmap (.bmp) files |
Export file formats w/SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Memory review | Sequential image navigation and review |
General specifications |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Display | 9.3 cm (3.7 in) |
Controls and adjustments | User selectable temperature scale (°C/°F) Language selection Time/Date set User selectable backlight: “Full Bright” or “Auto” |
Software | SmartView® full analysis and reporting software included |
Batteries | Internal rechargeable battery pack (included) |
Battery life | Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery charge time | 2.5 hours to full charge |
AC battery charging | AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains adapters included |
AC operation | AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz), ac mains adapters included |
Power saving | Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.0 |
Electromagnetic compatibility | Meets all applicable requirements in EN61326-1:2006 |
C Tick | IEC/EN 61326-1 |
US FCC | CFR 47, Part 15 Class B |
Vibration | 0.03 g2/Hz (3.8 grms), IEC 68-2-6
|
Shock | 25 g, IEC 68-2-29
|
Drop
| 2 meter (6.5 feet)
|
Size (H x W x L) | 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) |
Weight (battery included) | 1.2 kg (2.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard) |
Recommended calibration cycle
| Two-years (assumes normal operation and normal aging |
Supported Languages | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, and (Dutch and Hungarian in manual only) |