Specifications: | Amprobe 35XP-A Digital Multimeter |
DC Volts | Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V Resolution 100 μV Accuracy +/-(0.5 % rdg + 1 dgt) Input impedance 400 mV: >100 MΩ Input impedance 4 V: 10 MΩ Input impedance 40 V ~ 1000 V: 9.1 MΩ Overload protection 1000 VDC or 750 VAC rms |
AC Volts (45 Hz - 500 Hz) | Ranges 400 mV, 4 V, 40 V, 400 V, 750 V Resolution 100 μV Accuracy 45 Hz ~ 100 Hz on 400 mV range +/-(1.5 % rdg + 5 dgts) Accuracy on 4 V to 750 V ranges +/-(1.5 % rdg + 5 dgts) Input impedance 400 mV: >100 MΩ Input impedance 4 V: 10 MΩ Input impedance 40 V ~ 1000 V: 9.1 MΩ Overload protection 1000 VDC or 750 VAC rms |
DC Current | Ranges 400 μA, 4000 μA, 40 mA, 400 mA, 2 A Resolution 0.1 μA Accuracy on 400 μA to 400 mA ranges +/-(1.0 % rdg + 2 dgt) Accuracy on 2 A range +/-(2.0 % rdg + 3 dgts) Input protection 2 A/1000 V fast blow ceramic fuse 6.3_32 mm on A input Burden voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges) |
AC Current (45 Hz - 500 Hz) | Ranges 400 μA, 4000 μA, 40 mA, 400 mA, 2 A Resolution 0.1 μA Accuracy on 400 μA to 400 mA ranges +/-(1.5 % rdg + 5 dgts) Accuracy on 2 A range +/-(2.5 % rdg + 5 dgts) Input protection 2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input Burden voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges) |
Resistance | Ranges 400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ Resolution 100 mΩ Accuracy on 400 Ω to 4 MΩ ranges +/-(1.0 % rdg + 4 dgts) Accuracy on 40 MΩ range +/-(2.0 % rdg + 5 dgts) Open circuit volts 0.45 V dc typical, (-1.2 Vdc on 400 Ω range) Overload protection 1000 VDC or 750 VAC rms |
Capacitance | Ranges 4 nF, 40 nF, 400 nF, 4 μF, 40 μF, 400 μF, 4 mF Resolution 1 pF Accuracy on 4 nF to 4 μF ranges +/-(5.0 % rdg + 30 dgts) Accuracy on 40 μF to 400 μF ranges +/-(5.0 % rdg + 5 dgts) Accuracy on 4 mF ranges +/-(5.0 % rdg + 15 dgts) Test voltage < 1 V Test frequency on 4 nF to 40 μF ranges 1.3 Hz Test Frequency on 400 μF, 4 mF ranges 0.7 Hz Input protection 2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input |
Temperature | Ranges -20 - 1000 Degrees C, -4 - 1832 Degrees F Resolution 0.1 Degrees C, 0.1 Degrees F Accuracy -20 - 10 Degrees C +/-(2.0 % rdg + 4 Degrees C) Accuracy 10 - 200 Degrees C +/-(1.0 % rdg + 3 Degrees C) Accuracy 200 - 1000 Degrees C +/-(3.0 % rdg + 2 Degrees C) Accuracy -4 - 50 Degrees F +/-(2.0 % rdg + 8 Degrees F) Accuracy 50 - 400 Degrees F +/-(1.0 % rdg + 6 Degrees F) Accuracy 400 - 1832 Degrees F +/-(3.0 % rdg + 4 Degrees F) Overload protection 1000 VDC or 750 VAC rms |
Frequency | Ranges 4 k, 40 k, 400 k, 4 M, 40 MHz Resolution 1 Hz Accuracy +/-(0.1 % rdg + 3 dgts) Sensitivity 10 Hz ~ 4 MHz: >1.5 V rms Sensitivity 4 MHz ~ 40 MHz: >2 V rms, <5 V rms Minimum pulse width > 25 ns Duty cycle limits > 30 % and < 70 % Overload protection 1000 VDC or 750 VAC rms |
Continuity | Audible indication Less than 25 ? Response time 100 ms Overload protection 1000 VDC or 750 VAC rms |
Diode Test | Test current 1.2 mA (approximate) Accuracy +/-(1.5 % rdg + 3 dgts) Resolution 1 mV Open circuit volts 3.0 dc typical Overload protection 1000 VDC or 750 VAC rms |
Non-Contact Voltage Indicator | Sense voltage 70 V to 600 VAC beeper chirps and big bright red LED comes on, works on all ranges |
Display | 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 |
Polarity | Automatic, positive implied, negative polarity indication |
Overrange | (OL) or (-OL) is displayed |
Zero | Automatic |
Low battery indication | The low battery icon is displayed when the battery voltage drops below theoperating level |
Auto power off | Approx. 10 minutes |
Measurement rate | 2 times per second, nominal |
Operating environment | 0 to 50 Degrees C at <70 % R.H. |
Storage temperature | -20 to 60 Degrees C, 0 to 80 % R.H. with battery removed from meter |
Accuracy | Stated accuracy at 23 Degrees C +/- 5 Degrees C, <75 % relative humidity |
Temperature coefficient | 0.1 x (specified accuracy) per Degree C. (0 to 18 Degrees C, 28 to 50 Degrees C) |
Altitude | 6561.7 feet (2000 M) |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 150 hours typical with carbon-zinc, 300 hours typical with alkaline |
Dimensions | 155 mm (H) x 72 mm (W) x 32 mm (D) |
Weight | Approx. 400 g including battery |
Safety | Designed to meet IEC 1010-1, Rev-2 CAT I 1000V, CAT II 600V,CAT III 300V,Designed to meet IEC 1010-1, Rev-2 CAT I 1000V, CAT II 600V,CAT III 300V, class 2 and pollution degree 2 indoor use. Complies with CE and CSA 22.2 No. 1010-1 requirements. |
Auxiliary Features | Data hold Freeze the latest reading on the display; Range Execute manual range mode; AUTO power off; After auto power off, press any button to restart the meter, and the last reading of measurement will be maintained in the display; Jack Input warning detects wrong connection |
Temperature coefficient | 0.1 x (specified accuracy) per Degree C (0 to 18 Degrees C, 28 to 50 Degrees C) |
Power | Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 200 hours typical with carbon-zinc |
Weight | Approx. 210 g including battery |
Safety | Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements |
Auxiliary Features | Data hold Freeze the latest reading on the displayRange Execute manual range modeAuto power off After auto power off, press (RANGE), (HOLD) button to restart the meter,and the last reading of measurement will be maintained in the displayA jack Input warning detects wrong connection |