| Specifications | AEMC OX5022-CK Oscilloscope
|
| |
| Interface |
| Display | 3.5" color TFT LCD screen; Resolution 320x240 - LED backlighting |
| Commands | Direct adjustments on front panel & on-screen menus via browswer (principal & secondary without "hidden menus" |
| Display Mode | 2500 real acquisition points on screen |
| Display of Curves on Screen | 2 curces + 2 reference + memory trace or mathematical calculation |
| Integrated Interactive Help Function | 11 languages: French, English, German, Spanish, Italian, Swedish, Romanian, Russian, Finnish, Polish, Dutch |
| Oscilloscope Mode |
| Vertical Deflection | Bandwidth | 20MHz |
| Bandwidth Limiter | 1.5MHz, 5kHz |
| Number of Channels | 2 totally isolated channels |
| Input Impedance | 1MΩ ± 0.5%, approx. 17pF |
| Maximum Input Voltage | 600V CAT III - Derating -20dB per decade from 100kHz |
| Vertical Sensitivity | 5mV to 200V/div |
| Horizontal Deflection | Sweep Speed | 25ns/div to 200s/div - Roll Mode from 100ms to 200s/div |
| Horizontal Zoom | Zoom factor: x1, x2, x5 |
| Triggering | Mode | Automatic, triggered, one-shot & triggered Roll |
| Type | Edge, pulse width (20ns-20s) |
| Coupling | AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection |
| Sensitive | ≤ 1.2 divisions p-p up to 20MHz |
| Digital Memory | Maximum Sampling Rate | 2GS/s in ETS mode - 50MS/s in one-shot on each channel |
| Vertical Resolution | 9 bits |
| Memory Depth | 2500 points per channel |
| User Storage | 2MB for storing files: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp) |
| Glitch Mode | Duration ≥ 20ns - 1250 Min/Max pairs |
| Display Modes | Envelope, Averaging (factors 2 to 64) and XY (vector) |
| Other Functions | Math Functions | Channel inversion, addition, subtraction, multiplication and division (adjustable scaling) |
| Cursor Measurement | 2 cursors: V,T,dV,dt simultaneously - 4-digit display resolution |
| Automatic Measurement | 18 time or level measurements and phase measurement |
| Multimeter Mode |
| General Specifications | 2 channels, 8000-count display + min/max bargraph - Graphic recording of 2700 measurements (5min to 1 month) |
| Operation Modes | Absolute or relative display (absolute, deviation, ref, ref%) - Monitoring (instantaneous, Min, Max, Avg) |
| AC, DC & AC+DC Voltage | Ranges from 600mV to 600Vrms, 800mV to 800VDC - accuracy for VDC 1% reading + 20D - 50kHz bandwidth |
| Resistance | Range from 80Ω to 32MΩ - accuracy 2% reading + 10D - 10ms quick continuity test |
| Capacitance | Ranges from 5nF to 5mF - basic accuracy 2% reading + 10D |
| Other Measurements | Frequency, rotation speed, 3.3V diode test, temperature measurement (with K-type thermocople or infrared probe) |
| Power |
| Measurements | Single-phase and balanced three-phase active powre values (with or without neutral), simultaneous display of current |
| Harmonic Analyzer Mode |
| Multi-Channel Analysis | 2 channels, 31 orders, fundamental frequency from 40 to 450Hz |
| Simultaneous Measurements | Total VRMS, THD and selected order (% fundamental, phase, frequency, VRMS |
| General Specifications |
| Screenshots | Up to 100 files in standard ".bmp" format, viewable on the instrument |
| PC Communication | Isolated Optical USB interface "SX-Metro" PC application software |
| Power Supply | 6 LR6 or 6AA NiMh batteries - Battery life up to 8hrs 30min Universal line adapter isolated from the channels - Quick charging in 2hrs 30min |
| Safety / EMC | Safety according to IEC61010-1 Ed3 - 600V CAT III, EMC according to EN61000-3, 2001 & EN61326-1, 2006 |