Price matching available – call, chat with us or send an email request.Alnor EBT731 Balometer Multipurpose Electronic Air Balancing Instrument is a versatile electronic air balancing tool that can be used at diffusers and grilles to take direct air volume readings easily. It includes a removable micromanometer that can be used with optional probes in various measurement applications. EBT731 capture hood kit is lightweight and ergonomic that offers durable, reliable operation and saves time and money by combining multiple instruments into one package.Alnor EBT731 comes with: 2' x 2' (610 mm x 610 mm) air capture hood/frame/base, manometer with carrying case, 18 in. (46 cm) Pitot probe, (2) Static Pressure probes, 16 ft (4.8 m) Neoprene tubing, (4) AA size rechargeable NiMH batteries, multi-country AC adapter , wheeled luggage-style carrying case, USB interface cable, manual, NIST traceable calibration certification, and downloading software.
MFG Part No.: EBT731
Availability: Available for Orders, Coming Soon Free Shipping.
Get a Deal tsihood
Save w/ Promo Code: TSISALE
Price Match Guarantee Yes
The TSI EBT731 Balometer is the perfect ergonomic, lightweight, and multipurpose capture hood for accurately and efficiently taking pressure, velocity, and flow at diffusers and grilles to make sure that the ventilation system complies with industry standards. The EBT731 features a detachable micromanometer that can be used with optional probes for additional flexibility in different situations.

Key Features:
  • Comfortable design and light weight for one person operation
  • Accurate measurement of pressure, velocity, and flow to ensure compliance with industry standards
  • Automatically senses and displays supply and return flow
  • Back pressure compensation for accuracy
  • Different hood sizes available for different jobs
  • Detachable micromanometer for use in other applications and with additional optional probes
  • Auto-zeroing pressure sensor to save time
  • Auto-density correction for reading accuracy
  • User friendly backlit LCD display
  • Export data through USB cable or Bluetooth
  • Compatible with AiRNAB digital documentation system
The variety of well thought out features and functions of the EBT731 makes this the perfect instrument for HVAC commissioning, clean room certification, trouble shooting, as well as testing and balancing of HVAC systems. In addition, the ease of set up and the ultra-light weight (7.4 lbs) capture hood makes this easy for one person to operate. It also includes a NIST calibration and comes with a certificate.

The detachable micromanometer saves time with its auto-zeroing pressure sensor, increases accuracy with its auto-density correction, and has back-pressure compensation when used with the capture hood that ensures accurate readings.

The EBT731 micromanometer has an intuitive menu with a large, backlit graphic LCD that displays up to five simultaneous measurements, on-screen messages, and instructions.

The micromanometer for the EBT731 comes with an integrated Log-Tchebycheff duct traverse mapping application that simplifies calculations for air velocity and air volume within round or rectangular duct work.

The EBT731 comes with the 2’ x 2’ hood, but other hood sizes are available for different applications.

The EBT731 balometer includes the LogDat-Ch software that allows the capture hood and the micromanometer’s data to be transferred to a PC through the included USB cable for reporting and analysis. It also has Bluetooth communication for data transfer.

The EBT731 can also be purchased with a hood stand EBT731- STA for additional ability to reach ceilings as high as 15 feet.

The TSI Alnor EBT731 comes with:
2 ft. x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
Detachable micromanometer
(4) AA size rechargeable NiMH batteries
Multi-country AC adapter
18 in. (46 cm) Pitot probe
(2) Static Pressure probes
16 ft. (4.8 m) Neoprene tubing
Wheeled luggage-style carrying case
NIST traceable calibration certification
Downloading software
USB interface cable
Manual

Related Items

Alnor 6200 LoFlo Balometer Air Volume Capture Hood
(0)
$1,890.00 $1,701.00 Sale
Available for Orders, Coming Soon Free Shipping.
Alnor 6200F LoFlo Balometer Air Volume Capture Hood
(0)
$1,860.00 $1,674.00 Sale
In Stock. Free Shipping.
Alnor 6200D LoFlo Balometer Air Volume Capture Hood
(0)
$1,860.00 $1,674.00 Sale
Available for Orders, Coming Soon Free Shipping.
Testo 420 Balometer Flow Hood with Bluetooth and Soft Case
(0)
$3,495.00 $2,970.75 Sale
In Stock - Ships the Same Day Free Shipping.
Testo 420 Balometer Flow Hood with Bluetooth and Soft Case with NIST
(0)
$3,695.00 $3,140.75 Sale
Available for Orders, Coming Soon Free Shipping.
CPS Products ABM-HOOD Airflow Capture Hood Balometer EasyHood
(0)
$430.29 $372.92 Sale
Available for Orders, Coming Soon Free Shipping.

Mailing List

TOP
0 Items